Specifications

73
Mechanical Indicators
Specifications
Indicator type
Model name
Operation principle
Accuracy (driving needle) (grade)
Frequency
Wattemeters Receiving indicators
LB-11ZNW
LB-11YNW
LB-11ZRNW
LB-11YRNW
LB-11ZNRI
LB-11YNRI
LB-11ZRNRI
LB-11YRNRI
Instantaneous meter
Marker
needlesNeedles
Max. value
Min. value
Demand meter
Instantaneous meter
Scale
length
(mm)
Time interval (min)
Input
110V 5A
220V 5A
110V 5A
220V 5A
/110V5A
110/190V 5A
220/380V 5A
Phase-
wire
1-phase
2-wire
3-phase
3-wire
3-phase
4-wire
Marker needle reset
Model name
Auxiliary power supply
Accessories
Main body weight (kg)
Delivery period classification
Bimetal (Movable coil instantaneous meter) + transducer
1.5
50 and 60Hz
150
Bimetal (Movable coil instantaneous meter)
1.5
150
215215215215215215215215
Indicator rating (Po)
0.4~0.6kW
0.8~1.2kW
0.8~1.2kW
1.6~2.4kW
0.8~1.2kW
1.4~2.0kW
2.8~4.0kW
Consumption VA
Voltage circuit
3
6
3
6
1
1.5
1.5
I
1, I3
3.2
3.2
3.2
3.2
1.2
1.2
1.2
I
2
2.4
2.4
2.4
Indicator rating
1mA DC Internal resistance: 1kΩ
Manual and electromagnetic reset (electromagnetic reset rating: 100-110VAC/DC ±10%); consumption VA: approx. 5VA
T-150 rectifier/T-150LB DC amplifier
110V AC %; 50 and 60Hz; consumption VA: approx. 12VA
1.2
1.4
1.4
1.5
1.2
1.4
1.4
1.5
T-150LB DC amplifier
110V AC %; 50 and 60Hz; consumption VA: approx. 12VA
—50—50
110
3
+10
-15
+10
-15
Standard
product
Immediate delivery
Quasi-standard
product
Within 20 days
Special
product
21 to 60 days
Symbol
Reference delivery period
Delivery period classification
Wattmeters Time intervals: 2 and 15 minutes
The electricity demand, instantaneous electricity and maximum electricity demand can be
recorded. In addition, wattmeters can be used to monitor transformer load and electricity.
Receiving indicators Time intervals: 2 and 15 minutes
Receiving indicators are used in combination with various electrical transducers or
instrumentation transducers, such as those for measuring temperature, to perform telemeter
measurements (remote measurement).
Wattmeters/Receiving indicators
LB-11YNRI
(with max. and min. value
marker needles)
LB-11YRNW
(with max. and min. value marker
needles and instantaneous meter)
Wattmeter
Receiving
indicator
Model name
Model name
Phase-wire system
Cover type
Special specifications
Number of units
LB-11ZNW 3P3W
Time interval
2M
Indicator rating
110V 5A
CT ratio
50/5A
VT ratio
6600/110V
Scale
0-600kW
Colored lines, colored
bands, etc.
B
Cover type
Special specifications
Time interval
2M
Indicator rating
1mA
Scale
(0-100) A
Double scale, colored
lines, etc.
BLB-11ZNRI
The items in must be specified.
2
Number of units
2
Remarks
(1) Refer to the “Wattmeter Scale Selection Reference Table” (p.56) regarding the manufacturable
maximum scale value of a wattmeter.
(2) The T-150 rectifier and T-150LB DC amplifier are dedicated accessories (non-compatible). They can
only be used in combination with the indicators specified. The distance between the indicator and the
T-150LB DC amplifier/T-150 rectifier must be 5m or less, or the round trip lead wire resistance must
be 0.5Ω or less.
(3) Wattmeters cannot be manufactured with both positive and negative readings on the scale.
For receiving indicators with a positive/negative scale, use a transducer to convert positive/negative input to positive output (e.g., convert input of -1,000 to
0 to +1,000W to output of 0 to 0.5 to 1mA).
(4) For scales that measure in electrical units (A, V, W, var, cosø, Hz), AC/DC and three-phase circuit symbols are not displayed. For receiving indicators, the
symbol for the quantity to be input is displayed.
(5) Please make sure to read the “Safety Precautions” (pp.5-8) and the “Selection Precautions” (p.9) to assist in selecting the model and use specifications
suited to the application.
Max. value marker needle (red)
Driving needle (black)
Instantaneous meter needle (black)
only for LB-11YNW and LB-11YRNW
Min. value marker needle (green)
only for LB-11ZRNW and LB-11YRNW
Zero adjust knob
4-M5 mounting screws
Depth dimension
f100
26.3
17.3 15
M4 power supply terminal screw for
electromagnetic marker needle reset
M4 demand terminal screw
Panel hole opening dimensions
Manual pushbutton marker needle reset
110
110
45
4-f6
f104
45
90
45 45
90
RESET
D
E
M
A
N
D
M
E
T
E
R
M4 instantaneous meter input terminal screw
only for LB-11ZRNW and LB-11YRNW
Fig. 1 Indicator main body
Outer dimensions
Depth dimensions
Model name
LB-11ZNW
LB-11ZNRI
LB-11YNW
LB-11YNRI
LB-11ZRNW
LB-11ZRNRI
LB-11YRNW
LB-11YRNRI
Depth dimension
120
165
145
165
Demand Meters
Mechanical
Ordering method