Specifications

Mechanical Indicators
70
AC voltmeters
Using AC voltmeters with changeover switches, the voltages between the respective wires of a
3-phase, 3-wire system (or 1-phase, 3-wire system) circuit can be measured by a single meter.
Equipped with a protective circuit to protect the VT secondary circuit.
Specifications
Size (width height) mm
Model name
Operation principle
Accuracy (grade)
Frequency
Scale length (mm)
Weight (kg)
Indicator rating and delivery period classification
8299
YR-8UNAV
102119
YR-10UNAV
122139
YR-12UNAV
Rectifier
2.5
70
0.15
2.5
50 and 60Hz
90
0.2
VT ratio
440/110V
3300/110V
6600/110V
besides the above, 110V
Scale
0-600V
0-4500V
0-9000V
VT ratio 150V
Consumption
VA
0.5
1.2
2.4
0.5
0.5
Maximum scale
150V
300V
600V
Delivery period classification
1.5
100
0.4
Combined
with VT
Direct
Standard
product
Immediate delivery
Quasi-standard
product
Within 20 days
Special
product
21 to 60 days
Symbol
Reference delivery period
Delivery period classification
YR-10UNAVYR-8UNAV
Outer dimensions
Fig. 1 YR-8UNAV
Fig. 2 YR-10UNAV
Fig. 3 YR-12UNAV
Connection diagrams
Fig. 1 Direct
Fig. 2 Combined with VT
Unnecessary in the case of a direct indicator.
Model name VT ratio
Cover type
Special specifications
YR-8UNAV 150V B440/110V
Scale
0-600V
With 1-3 nameplate, colored
lines, colored bands, etc.
Indicator
rating
The items in must be specified.
Number of
units
10
OFF
R-S
S-T T- R
Zero adjust button
82
17
82
10
60
2-M3 mounting screws
12.5
13.5
14.5
M4 terminal screw
f65.5
f67
32 32
32 32
2-f4
Panel hole opening dimensions
(as viewed from front face of the panel)
OFF
R-S
S-T T-R
Zero adjust button
102
102
17
10
60
2-M4 mounting screws
12.5
13.5
14.5
M4 terminal screw
f85
f88
4040
4040
2-f5
Panel hole opening dimensions
(as viewed from front face of the panel)
OFF
R-S
S-T T-R
Zero adjust button
122
f110
17
15
50
2-M5 mounting screws
12.5
13.5
19
M4 terminal screw
122
f113
50 50
50
50
2-f6
Panel hole opening dimensions
(as viewed from front face of the panel)
12
3
Load
P
1
P3
P2
12
3
Load
P
1
P3
P2
Note 1
VT
(1) In the case of a 1-phase, 3-wire system circuit (100/200V), use a model rated at 300V direct.
(2) A switch nameplate for 1-phase, 3-wire systems can be manufactured. Please specify “with 1-3
nameplate.”
Nameplate examples: OFF R-N N-S R-S OFF R-N N-T R-T Make sure to specify the indication
contents when ordering.
(3) Supplementary anti-corrosion treatment is not possible.
(4) Please make sure to read the “Safety Precautions” (pp.5-8) and the “Selection Precautions” (p.9) to assist in
selecting the model and use specifications suited to the application.
Remarks
Ordering method
For low-voltage circuits, grounding of the secondary side
of the instrument voltage transformer is unnecessary.
Note 1.