Specifications
167
Transducers
Special Application Transducers
T-120HA harmonics transducers [Insulated]
110V 220V
110V
220V
440V
1100V
2200V
3300V
6600V
11kV
13.2k V
16.5k V
22kV
33kV
66kV
77kV
110kV
132kV
154kV
187kV
220kV
275kV
550kV
SP
5A
6A
7. 5A
8A
10A
12A
15A
20A
25A
30A
40A
50A
60A
75A
80A
100A
120A
150A
200A
250A
300A
400A
500A
600A
750A
800A
1000A
1200A
1500A
1600A
2000A
2500A
3000A
4000A
5000A
6000A
7500A
8000A
10kA
12kA
20kA
25kA
30kA
SP
P01
P02 P0 3
(1) (3) (5) (7) (11) (13): order of harmonic wave,
Σ: Overall harmonic wave, rms: Overall effective value
P01 V
P02 I
P03 V
CH1 CH2 CH3
(1)
V
(3)
V
(5)
(1)
I
(3)
I
(5)
(3)
V
(5)
V
(7)
CH4 CH5 CH6 CH7 CH8 CH9
V
(7)
V
(11)
V
(13)
ΣV ΣI
HH
I
(7)
I
(11)
I
(13)
ΣV ΣI
H
I
(3)
I
(5)
I
(7)
H
ΣV ΣI
CH10
Irms
Irms
HH
Vrms
Vrms
Vrms Irms
RETUR
N
SET
RETURN SET
RETURN
SET
RETURN
SET
SET
Analog output
pattern
Operation indicator
Lit during operation.
Output channel display
Displays the output channel to be set.
Output limit setting indicator
Lit when setting of output limit.
Harmonics measurement setting indicator
Lit when setting harmonics measurement.
Demand time interval setting indicator
Lit when setting of demand time
interval for harmonics.
Harmonics measurement pattern display
Displays the measurement pattern to be set.
%: content (%) RMS: effective value
Setting indicators are lit when
setting the corresponding item.
Basic setting indicator
Analog output setting indicator
Zero adjust indicator
Span adjust indicator
Test indicator
Lit during analog output testing.
Digital display, unit indicator
The respective setting values are
displayed.
qSetting menu
qChange the setting menu to indicate .
e
Secondary voltage
eSet the secondary voltage.
r
Primary voltage
rSet the primary voltage.
wSet the analog output pattern.
buttons
buttons
buttons
buttons
buttons
buttons
w Analog output
pattern
Measurement elements
• If the secondary voltage is set to 220V in e, setting of the
primary voltage will be skipped.
• When SP is selected, setting the special primary voltage
is required, in which the upper three digits can be set in the
range of 110V to 550kV.
• When SP is selected, setting of the special primary current
is required, in which the current can be set in the range of 5A to
30kA in using the following steps.
5A~100A : in steps of 5A
100A~1000A : in steps of 10A
1000A~10kA : in steps of 100A
10kA~30A : in steps of 1kA
t
Primary current
tSet the primary current.
ySetting menu
SET
y Continue set up in another
setting menu or end set up.
To change to another setting menu,
use the and buttons to
select the setting menu in which
set up is to be performed.
SET
SET
To end set up
Use the and buttons to select End.
Use the button to display SAVE, and
then save the settings by pressing the
button again.
To cancel the settings
When SAVE is displayed, use the and
buttons to select CANL and then press
the button to cancel the settings.
SET
Setting mode
Press the button for 2s or more to enter the set up mode (setting menu will be displayed and “End” will blink).
Use the and buttons to select the item to be set, press the button to display the set up screen,
and then use the and buttons to set the contents.
When the button is pressed for 1s or more while setting an item, setting of the remaining items is
skipped and returns to the setting menu.
Basic settings (analog output pattern, primary/secondary voltages, primary current)
SET
SET
SET
[Display unit]
Setting Method