Specifications

151
Transducers
Handling
T-51/T-101 Series
Method for mounting inside panels
Mounting work is to be performed by a person with the proper technological expertise.
The following four types of mounting can be performed for models with standard
specifications. The mounting parts can be used according to application.
Accessories
Mounting legs are packaged together with the
main unit as accessories.
(1) Using mounting legs
Press-fit
Mounting legs
T-51
T-101
A “mounting leg”
can be removed by
pulling out the leg
while lifting the root
portion of the leg
with a standard
screwdriver.
q
w
(2) Using an IEC 35mm rail
(3) Using a breaker mounting plate for distribution panel
(4) Using a breaker coupling/mounting tabs for distribution panel
(1) Mounting legs (2) IEC 35mm rail
(3)
Breaker mounting plate
for distribution panel
(4)
Breaker coupling/mounting
tabs for distribution panel
T-51
T-101
Applicable IEC 35mm rail Mounting Removal
Outer shape of mounting plate Mounting
Outer shape of mounting tabs Mounting
One main unit Two mounting legs
One main unit Four mounting legs
35
27
1
7.3 or more
qLatch on
IEC 35mm rail
wPush in
q
q
Pull down the IEC 35mm rail removal tab
wPull upw
f5.5 mounting holeParting groove
q
w
qLatch on
wPush in
Inserted spring
f4.5 mounting hole (slot)Parting groove
M4 mounting screw
* When mounting using an IEC 35mm rail, affix the unit using a stopper to prevent sliding to the side.