Specifications

13
Products List
Indicator Line-up,
Precautions & Specifications
1. Rectangular Indicators (Y-2N Series, Y-N Series)
Indicator type
Appearance
Model name
Y- 2 N
Series
Y- N
Series
Size (mm)
6460
8575
10085
8282
102102
122122
Operation principle
Indicator ratings
Direct
Combined with shunt,
multiplier, or transformer
Scale
Cover
Ordinary
Expanded
Black (B)
Transparent
(G)
Special color coating
(F)
Special specifications
Red needle
Special accuracy class
Foreign standards
Special environment
Double scale
Colored lines/bands
Shunt
Lead wires
Lead wire adjustment resistor
Page with specifications table
DC ammeters
YM-206NDA
YM-208NDA
YM-210NDA
YM-8NDA
YM-10NDA
YM-12NDA
Movable coil
Note 1
100, 200, 300, 500mA
1, 3, 5, 10, 20, 50mA
100, 200, 500mA
1, 2, 5, 7.5, 10, 15, 20, 30A
1~7500A
(combined with shunt)
(Class 1.5)
(Class 1)
(Class 1.5)
(Class 1)
(Class 1.5)
(Class 1)
(Class 1.5)
(Class 1)
(Class 1.5)
(Class 1)
(Class 1.5)
(Class 1)
43
YM-206NDV
YM-208NDV
YM-210NDV
YM-8NDV
YM-10NDV
YM-12NDV
Movable coil
Note 2
1, 3, 5, 10, 15V
30, 50, 100, 150V
300, (500), (600)V
750~2000V
(combined with multiplier)
47
DC voltmeters
YS-206NAA
YS-208NAA
YS-210NAA
YS-8NAA
YS-10NAA
YS-12NAA
Movable iron core
Note 1
500mA
1, 3, 5, 10A
15, 20, 30A
5A, 1A
(combined with current transformer)
49
Non-uniform scale
YR-206NAA
YR-208NAA
YR-210NAA
YR-8NAA
YR-10NAA
YR-12NAA
Rectifier
Note 1, 2
(200), (300), 500mA
1, 3, 5, 10, 20, 30, 50mA
75, 100, 200, 500mA
1, 3, 5, 10, 15, 20, 30A
5A, 1A
(combined with current transformer)
50
Uniform scale
YS-206NAV
YS-208NAV
YS-210NAV
YS-8NAV
YS-10NAV
YS-12NAV
Movable iron core
Note 2
50, 150, 300V
(600)V
150V
(combined with instrument voltage transformer)
51
Non-uniform scale
YR-206NAV
YR-208NAV
YR-210NAV
YR-8NAV
YR-10NAV
YR-12NAV
Rectifier
Accuracy (class) 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5
Note 2
5, 10, 30, 50, 75V
100, 110, 150, 190V
260, 300, (400)V
(500), (600)V
150V
(combined with instrument voltage transformer)
52
Uniform scale
Note 3
Note 4
AC ammeters AC voltmeters
Remarks
Note 1.
Note 2.
Note 3.
Note 4.
All indicators, excluding special grade and foreign standard specification indicators, comply with the Japanese Industrial Standards relating to direct-acting
electrical indicators and have the JIS mark.
However, the JIS mark may not apply depending on the operating circuit voltage or rated voltage. Refer to the Reference Chart for Test Voltages and JIS Mark
on p.25/26 for details.
The operating circuit voltage is 300V or less for the Y-2N Series and 600V or less for the Y-N Series.
Parentheses ( ) indicate that some models cannot be manufactured with this rating. Refer to the specifications tables starting on p.45 for details.
Some models cannot be manufactured for some ratings. Refer to the specifications tables starting on p.45 for details.
Please designate the frequency if a special accuracy class is required for an AC indicator.