Specifications

129
Transducers
Isolators [Insulated]
Isolators provide insulation between DC circuits and measurement equipment,
and between various sensors and control equipment.
Isolators can be used as a buffer or level exchange between input/output.
Applications
Insulation between DC circuits and measurement equipment
Insulation interface between each sensor and other equipment such as computers or data loggers
Insulation between separate circuits
T-51/T-101 Series
T-101!S
Outer shape
Box
Model
name
Accuracy
(grade)
Input (DC) and input resistance
Auxiliary
power supply
Weight
Delivery period
classification
Output (DC)
Voltage or current and load
Ripple/Response speed
60mV
1V
5V
10V
1~5V
1mA
5mA
4~20mA
100kΩ or more
Input voltage drop
:
200mV or less
1mA : 0~5kΩ
5mA : 0~1kΩ
4~20mA : 0~600Ω
100mV : 5kΩ~
1V : 5kΩ~
5V : 5kΩ~
10V : 10kΩ~
1~5V : 5kΩ~
T-101!S 0.25
1% P-P or less
0.5s or less
0.6kg
110VAC
%
50 and 60Hz
Consumption
VA: 3
Dielectric
strength between
input and output
2000VAC
2000VDC
for 1min
+10
-15
150V : 300kΩ or more
300V : 600kΩ or more
Standard
product
Immediate delivery
Quasi-standard
product
Within 20 days
Special
product
21 to 60 days
Symbol
Reference delivery period
Delivery period classification
Resistance between input terminals
Combine with a shunt if the current input exceeds 0.1A.
Isolators that provide positive/negative bidirectional output or positive direction-only output for
positive/negative bidirectional input can also be manufactured.
The manufacturable ranges for a bidirectional output are ±50mV~±10V and ±0.1~±5mA.
Please inquire separately regarding input specifications exceeding 300V.
*1
*2
*3
*4
Input
Input resistance
60mV~50V
100kΩ
over 50V~300V
2kΩ
/V
0.5mA~0.1A
Input voltage drop: 200mV or less
Input 60mV~300V, 0.5mA~0.1A
0.1~20mA, 50mV~10V
100, 105, 110, 115, 120V
%
200, 210, 220, 230, 240V
24V±10%
T-101!S
Output
*4
Auxiliary
power
supply
DC
AC
+10
-15
Manufacturable range
Specify three values for bidirectional output.
Model name
T-101!S
Number of units
7
Auxiliary power supply
110VAC
Output
Voltage or current
0-1mA
Input
Voltage or current
60mV
Usage examples
For measurement of a DC circuit For input interface of devices such as a calculator
Isolator
T-101IS
Shunt
Load
Isolator
T-101IS
Measurement
equipment or
sequencer
Isolator
T-101ISQ
Machine
A
Calculator
or
sequencer
Isolator
T-101ISQ
Machine
B
Isolator
T-101ISQ
Sensor
Ordering method