Indicator Line-up,
Precautions & Specifications
Special Specifications
SpecificationApplication
Moisture-proof
treatment
Supplementary
anti-corrosion
treatment
Indicator
AC ammeter, AC voltmeter
Wattmeter, varmeter, power factor meter
Frequency meter
Applicable models
Rectifying
Transducer
Transducer
Applicable range (max.)
Approx. 1000Hz
400Hz
400Hz (scale: 360~440Hz)
Standard
(Vertical)
(Horizontal)
Example of mounting
angle designation
ANGL (Horizontal)
Example of mounting
angle designation
ANGL (150°)
Example of mounting
angle designation
ANGL (30°)
30°
150°
Mounting attitude The standard attitude for mounting indicators is vertical.
Please specify the mounting angle if a non-standard mounting attitude is required.
High humidity Moisture-proof treatment
Use of indicators in high-humidity environments may cause mold to grow or the insulation resistance to deteriorate.
To prevent this, a special moisture-proof coating and anti-corrosion plating are used.
Applicable models: Y-2N Series, Y-N Series, L-N Series, F-N Series
A “moisture-proof” sticker is attached to products that have been treated.
This treatment cannot be applied to some models. Please contact a Mitsubishi Electric representative for details.
Corrosive gases Supplementary anti-corrosion treatment
This treatment is a simplified anti-corrosion treatment for environments where the level of corrosive gases is low. (In
environments where there is a high level of corrosive gases such as at sewerage-/water-treatment, rubber or
chemical plants, indicators are generally protected with anti-corrosion casings.)
The treatment involves use of a sealed structure and anti-corrosion plating.
Applicable models: Y-2N Series, Y-N Series, and L-N Series
A supplementary anti-corrosion sticker is attached to products that have been treated.
This treatment cannot be applied to some models. Please contact a Mitsubishi Electric representative for details.
High-frequency circuits
Use the following models for high-frequency circuits with which the commercial frequency of 50 to 60Hz is
exceeded.
Please specify the frequency when ordering.
Products complying with foreign
standards
Products that comply with foreign standards such as ANSI and BS can also be manufactured.
When ordering, please specify the relevant standards and frequency.
Models with JIS indications comply with IEC standards (no changes necessary).
Please note that the products in this catalog do not have the CE mark.
Special characters and symbols
Please clearly specify the language and font settings required (for example, Japanese or English characters;
uppercase or lowercase characters).
Orders without language/font settings specified will be manufactured according to Mitsubishi Electric’s standard
specifications (lowercase English characters, Helvetica regular font).
Special scale models
Special scale models can be manufactured (please submit detailed diagrams).
In cases where the indicator input and the scale values are not proportional, please submit an input-scale
conversion table.
The information in the following table relates to special specifications for mechanical indicators. Please contact a Mitsubishi Electric