Specifications
Mechanical Indicators
104
Tag number plate
Standard screwdriver
Extraction pin
Standard screwdriver
Pressure tag number plate
F-217N
Pivoting tag number plate
F-210N, 213N, 215N
4. Disassembling of nameplates, tag number plates, covers and scale plates
Procedure 1.Remove the nameplate and tag number plate.
For pivoting tag number plates, remove the extraction pins at the rear. Remove while lifting the indicator
approximately 5mm from the panel surface.
(The pivoting tag number plate does not need to be removed to remove the scale plate.)
2.Remove the cover fastening screws.
3.To remove the cover, pull the upper side of the cover forward slowly and then lift slightly.
Nameplate
Tag number plate
(F-217N)
Cover fastening screws
Cover
Needle
Tag number plate
(F-210N, 213N, 215N)
Main unit
4.To prevent deformation of the needle, turn the zero-point
adjuster and move the needle to the lower side.
5.Draw out the scale plate wedge toward the front.
6.The scale plate can be removed when the upper side
(nameplate side) of the scale plate is slowly drawn
outward and lifted slightly.
Note: Be careful not to deform the needle when removing
the scale plate.
Pointer
Scale plate
Scale plate wedge
(upper)
Scale plate wedge
(lower)