Self diagnosis function
We are constantly trying to do better service to our customers by installing such judges that show abnormality of each function as follows:
SRK-ZD
Outdoor heat exchanger fluid pipe
sensor error
Outdoor temperature sensor error
Trouble of outdoor unit
Over current
Broken outdoor sensor wire, poor connector connection
Compressor locking, open phase on compressor output,
shortcircuit on power transistor, closed service valve
Current cut
Description of trouble
Room temperature sensor error
Cause
Broken heat exchanger sensor wire, poorconnector
connection
Indoor fan motor error
Heat exchanger sensor error
2 time flash
6 time flash
TIMER lamp ON
1 time flash
RUN lamp
2 time flash
1 time flash
TIMER lamp
2 time flash
3 time flash
1 time flash
RUN lamp keeps flashing
Over heat of compressor
Error of signal transmission
5 time flash
6 time flash
RUN lamp ON
Broken room temperature sensor wire, poor connector connection
Defective fan motor, poor connector connection
Broken heat exchanger fluid pipe sensor wire, poor connector
connection
Broken power transistor, broken compressor wire
Broken discharge pipe sensor wire, poor connector connection
Compressor blockage
Overload operation, overcharge
Gas shortage, defective discharge pipe sensor, closed control
valve
Defective power supply, Broken signal wire, defective in/outdoor
unit boards
2 time flash
RUN lamp 2 time flash
Rotor lock
Defective compressor
Open phase on compressor
Defective outdoor unit boards
4 time flash Discharge pipe sensor error Broken discharge pipe sensor wire, poor connector connection.
Outdoor heat exchanger fluid pipe
sensor error
Outdoor temperature sensor error
Broken outdoor sensor wire, poor connector connection
Description of trouble
Room temperature sensor error
Cause
Broken heat exchanger sensor wire, poorconnector
connection
Indoor fan motor error
Heat exchanger sensor error
2 time flash
6 time flash
TIMER lamp ON
1 time flash
RUN lamp
2 time flash
1 time flash
TIMER lamp
RUN lamp keeps flashing
Broken room temperature sensor wire, poor connector connection
Defective fan motor, poor connector connection
Broken heat exchanger fluid pipe sensor wire, poor connector
connection
4 time flash
Compressor dome sensor error.
Broken compressor dome sensor wire, poor connector connec-
tion.
Compressor locking, closed control valve
Current cut
1 time flash
Over heat of compressor
Error of signal transmission
5 time flash
6 time flash
RUN lamp ON
Gas shortage, defective discharge pipe sensor, closed control
valve
Defective power supply, Broken signal wire, defective in/outdoor
unit boards
2 time flash
Compressor failure, overload operation
Trouble of outdoor unit
SRK-HD, SRK-CD
Outdoor fan motor error
7 time flash
(20, 25, 35 type only)
Defective fan motor, poor connector connection