User`s manual

4
Inverter Heat Pump (High COP).
Indoor SRK20ZJX-S SRK25ZJX-S SRK35ZJX-S SRK50ZJX-S SRK60ZJX-S
Outdoor SRC20ZJX-S SRC25ZJX-S SRC35ZJX-S SRC50ZIX-S SRC60ZIX-S
Power Supply Outdoor Unit 1 Phase 230V 50Hz
Capacity
Cooling T1
kW
2.0(0.9-3.1) 2.55(0.9-3.2) 3.5(0.9-4.1) 5.0(0.7-6.2) 6.0(0.8-6.8)
Heating H1 2.5(0.9-4.3) 3.13(0.9-4.7) 4.3(0.9-5.1) 6.0(0.7-8.8) 6.8(0.8-9.7)
Heating H2 3.52 3.79 4.04 6.33 6.88
Input
Cooling T1
kW
0.35(0.19-0.7) 0.49(0.19-0.82) 0.845(0.19-1.01) 1.3(0.2-2.2) 1.86(0.25-2.3)
Heating H1 0.45(0.23-1.0) 0.595(0.23-1.12) 0.96(0.23-1.35) 1.35(0.2-2.26) 1.67(0.25-2.7)
Heating H2 0.984 1.095 1.256 2.133 2.529
Energy Label
Cooling
Stars
6 5 3 2.5 1.5
Heating 5.5 5.5 3.5 3.5 3
Energy Star Yes Yes Yes Yes No
EER Cooling T1 5.71 5.20 4.14 3.85 3.23
COP Heating H1 5.56 5.26 4.48 4.44 4.07
COP Heating H2 3.58 3.46 3.22 2.97 2.72
Current
Cooling
Amp
1.8 2.4 3.8 5.7 8.2
Heating 2.2 2.9 4.4 5.9 7.3
Recommended Circuit Breaker 16
Sound Power Level (JIS C9612)
Cooling Outdoor
dB(A)
60 60 63 62 65
Heating Outdoor 59 60 62 62 65
Sound Pressure Level (JIS C9612)
Cooling Indoor
dB
39/30/21 41/31/22 43/33/22 45/38/26 47/38/26
Heating Indoor 38/33/25 41/34/27 42/35/27 45/38/32 45/39/33
Air ow
Cooling Indoor
l/s
191-133-83 208-150-83 225-158-83 225-183-133 241-208-141
Heating Indoor 200-158-116 216-166-125 233-183-134 275-241-175 283-250-183
External Dimensions (HXWXD)
Indoor
mm
309X890X220
Outdoor 595X780(+62)X290 640X800(+71)X290
Net Weight
Indoor
kg
15
Outdoor 38 43
Refrigerant Piping
Liquid Line
mm
Ø6.35
Gas Line Ø9.52 Ø12.7
Connection Method Flare
Refrigerant R410A
Quantity kg 1.2 1.4
Pre Charged To Pipe Length m 15
Clean Filter Alergen Clear & Photocatalytic
SRK-ZJX
Wall Mounted type
R410A
SRK20ZJX-S / SRK25ZJX-S
SRK35ZJX-S
10m
15m
Maximum height difference
Maximum pipe length
Refrigerant pipe length
SRK50ZIX-S / SRK60ZIX-S
20m
30m
Maximum height difference
Maximum pipe length
SRC20ZJX-S SRC25ZJX-S
SRC35ZJX-S
SRK20ZJX-S / SRK25ZJX-S / SRK35ZJX-S / SRK50ZJX-S / SRK60ZJX-S
SRC50ZIX-S / SRC60ZIX-S
All SRK-ZJX series can be selected for use as
indoor units in combination with the SCM Multi
system outdoor unit.
Single
Single
Multi
Multi
FUNCTIONS
Comfortable Functions
Allergen
Filter
Allergen
Filter
Allergen
Filter
SUN
Filter
SUN
Filter
SUN
Filter
Comfortable Air Flow Functions
Auto Flap
Memory
UP/DOWN
Auto
Lateral
Swing
Positioning
of
installation
Convenient & Economy Functions
On Timer
24h Timer
Economy
DRY
OFF Timer
Sleep
Others
Restart
Auto
Back-up
Switch
Luminous
24h ION
Maintenance & Prevention Functions
MC
Diagnostic
Self
Detachable
Self Clean
Operation
Self Clean
Operation
Self Clean
Operation
Allergen
System
Allergen
System
Allergen
System