User`s manual
11
Residential Air Conditioners
SCM**ZJ series
SCM40ZJ-S SCM50ZJ-S SCM60ZJ-S SCM71ZJ-S SCM80ZJ-S SCM100ZJ-S1 SCM125ZJ-S1
2 Rooms 2~3 Rooms 2~4 Rooms 4~5 Rooms 4~6 Rooms
Power supply Outdoor 1ph 230 50Hz
Capacity
Cooling T1 kW 4.0(1.8~5.9) 5.0(1.8~7.1) 6.0(1.8~7.5) 7.1(1.8~8.8) 8.0(1.8~9.2) 10.0(1.8~12.0) 12.5(1.8~14.0)
Heating H1 kW 4.5(1.4~6.9) 6.0(1.4~7.5) 6.8(1.5~7.8) 8.6(1.5~9.4) 9.3(1.5~9.8) 12.0(1.8~13.5) 13.5(1.5~14.0)
Input
Cooling T1 kW 0.84 1.08 1.43 1.74 2.16 2.86 3.90
Heating H1 kW 0.90 1.31 1.51 2.00 2.26 2.93 3.25
EER Cooling T1 4.76 4.63 4.20 4.08 3.70 3.50 3.21
COP Heating H1 5.00 4.58 4.50 4.30 4.12 4.10 4.15
Current
Cooling T1 A 3.7 4.7 6.5 7.6 9.4 12.4 17.0
Heating H1 A 4.0 5.8 6.8 8.8 10 12.8 14.1
Sound power level (JIS C9612)
Cooling(Outdoor) dB (A) 60 62 63 65 66 68 69
Heating(Outdoor) dB (A) 62 65 65 66 66 71 72
External dimensions (HXWXD) mm 640X850X290 750X880X340 945X970X370
Net weight Outdoor kg 47 48 49 62 92
Refrigerant piping
Liquid line mm(in) Ø6.35(1/4") X 2 Ø6.35(1/4") X 3 Ø6.35(1/4") X 3 Ø6.35(1/4") X 4 Ø6.35(1/4") X 4 Ø6.35 X 5 Ø6.35 X 6
Gas line mm(in) Ø9.52(3/8") X 2 Ø9.52(3/8") X 3 Ø9.52(3/8") X 3 Ø9.52(3/8") X 4 Ø9.52(3/8") X 4 Ø9.52 X 5 Ø9.52 X 6
Union mm (Ø9.52⇒Ø12.7) X 1 (Ø9.52⇒Ø12.7) X 2 (Ø9.52⇒Ø12.7) X 2 (Ø9.52⇒Ø12.7) X 2 (Ø9.52⇒Ø12.7) X 2 (Ø9.52⇒Ø12.7) X 2
Connection method Flare connection
Refrigerant R410A
Volume kg 2.0 2.5 3.15 6
Pre-Charged 30 40 50
Indoor Unit Combination
SRK*ZJ
kW
2.0,2.5,3.5 2.0,2.5,3.5,5.0 2.0,2.5,3.5,5.0
SRK*ZJX 2.0,2.5,3.5 2.0,2.5,3.5,5.0 2.0,2.5,3.5,5.0,6.0 2.0,2.5,3.5
SRK*ZJX-S1 5.0,6.0
SRK*ZK-S 7.1
SRF*ZJX 2.5,3.5 2.5,3.5,5.0 2.5,3.5
SRF*ZJX-S1 5.0
SRR*ZJ 2.5,3.5 2.5,3.5,5.0 2.5,3.5,5.0,6.0
FDTC*VD 2.5,3.5 2.5,3.5,5.0 2.5,3.5,5.0,6.0
Indoor Unit Connection 2 Units 2 to 3 Units 2 to 4 Units 4 to 5 Units 4 to 6 Units
Indoor Connection Capacity kW 4.0kW to 6.0kW 4.0kW to 8.5kW 4.0kW to 11.0kW 4.0kW to 12.5kW 4.0kW to 13.5kW 8.0 kW to 16kW 8.0kW to 19.5kW
Note 1 Rated data is measured using SRK*ZJX indoor unit at an equilivant indoor/ outdoor capacity
Note 2 Currently there is no energy labelling standard for this type of product