FDUA/M Series Inverter Ducted Air Conditioners MHIAA is proudly sponsoring Monika’s Doggie Rescue
FD Series. Inverter Ducted Air Conditioners. A Mitsubishi Heavy Industries ducted system lets you and your family enjoy the comfort of powerful air conditioning in every part of your home all year round. Quiet, efficient and reliable our ducted systems have a 5 year warranty so you can be sure you’ll get quality air conditioning for years to come. FDUA.
FDUA Indoor Unit. Duct Connected - High Static Pressure. Products Automatic external static pressure (E.S.P.) control By using a DC motor, the optimum air flow volume can be achieved by this automatic control. The indoor unit will recognize external static pressure automatically and keep rated air flow volume. New FDUA Duct Duct Longer Duct Ceiling Keep the same air flow volume Setting No. 1 E.S.P.
FDUA Indoor Unit. Duct Connected - High Static Pressure. Wired Remote Control RC-EX1A Wireless Remote Control RC-E5 RCH-E3 RCN-KIT3-E Wired Remote Control W FduA71~160VF RC-EX1A RC-E5 RCH-E3 Dimension H 398 H 280 (1) Indoor units Model FDUA71VF 65 39 Drain can be discharged upwards by 600mm from the ceiling surface. It allows a piping layout with a high degree of freedom depending on the installation location.
FDUA FDUA100VNVF FDUA100VNXVF FDUA125VNXVF FDUA140VNXVF FDUA160VSVF FDUA71VF FDUA100VF FDUA100VF FDUA125VF FDUA140VF FDUA160VF Outdoor FDC71VNX FDC100VN FDC100VNX FDC125VNX FDC140VNX Power supply Outdoor Unit Cooling T1 Capacity Heating H1 Input FDC160VS 1 Phase 230V 50Hz kW 3 Phase 415V 58Hz 7.1 (3.2-8.0) 10 (4.0-11.2) 10 (4.0-11.2) 12.5 (5.0-14.0) 14.0 (5.0-14.5) 16.0 (7.0-20.0) 8.0 (3.6-9.0) 11.2 (4.0-12.5) 11.2 (4.0-12.5) 14.0 (4.0-17.0) 16.0 (4.0-18.0) 18.0 (7.6-22.
With flexible set up options, you can tailor a Mitsubishi Heavy Industries ducted system to suit the needs of your family and home. Talk to one of our dealers today to discuss how to design a ducted system that’s right for you. FDUA.
FDUM Indoor Unit. Duct Connected - Medium Static Pressure. Products Automatic external static pressure (E.S.P.) control By using a DC motor, the optimum air flow volume can be achieved by this automatic control. The indoor unit will recognize external static pressure automatically and keep rated air flow volume. New FDUM Duct Duct Longer Duct Ceiling Keep the same air flow volume E.S.P. button Setting No. No.1 No.2 No.3 No.4 No.5 No.6 No.7 No.8 No.9 E.S.P.
FDUM Indoor Unit. 8 Duct Connected - Medium Static Pressure. Wired Remote Control RC-EX1A Wireless Remote Control RC-E5 RCH-E3 RCN-KIT3-E Wired Remote Control RC-EX1A RC-E5 Thin design Drain can be discharged upwards by 600mm from the ceiling surface. It allows a piping layout with a high degree of freedom depending on the installation location. The height of all FDUM models is only 280mm.
FDUM FDUM50ZJXVF Outdoor Power supply FDUM71VNXVF FDUM100VNVF FDUM125VNXVF FDUM140VNXVF FDUM50VF FDUM60VF FDUM71VF FDUM100VF FDUM125VF FDUM140VF SRC50ZJX-S SRC60ZJX-S FDC71VNX FDC100VN FDC125VNX FDC140VNX 5.0 (2.2-5.6) 5.6 (2.8-6.3) 7.1 (3.2-8.0) 10.0 (4.0-11.2) 12.5 (5.0-14.0) 14.0 (5.0-14.5) 5.4 (0.6-6.3) 6.7 (0.6-7.1) 8.0 (3.6-9.0) 11.2 (4.0-12.5) 14.0 (4.0-17.0) 16.0 (4.0-18.0) Outdoor Unit 1 Phase 230V 50Hz Cooling T1 Capacity Heating H1 Input kW Heating H2 4.3 4.
Simple setting by tapping button only Run / Stop High power operation Energy-saving operation Maximum capacity operation (Max 15 minutes) • Increased compressor speed • Increased air flow • Changes set temperature at 28ºC in cooling mode and 22ºC in heating mode, 25ºC in auto mode.
Easy operation coNtroL Advanced touch screen panel with full dot Liquid Crystal Display All settings done by tapping touch screen panel Operation mode setting screen Setting temperature screen The operation mode can be selected by simply tapping this button. You can select the desired temperature by tapping the ▲▼ button.
Advanced Technology. Our advanced technology has allowed us to achieve high efficiency, powerful heating and long distance refrigerant piping specifications. This feature permits installation of the units when a heating operation under temperature conditions down to -20˚C is required. Design flexibility has been improved by an extension of the refrigerant piping length to 100m (12.5 & 14.0kW). Blue Fin Micro 5.0 & 6.0kW 7.1kW Blue Fin 10.0kW Long piping (in case of 12.5 & 14.
Powerful heating capacity Heating capacity (in case of 12.5kW) (kW) 18.0 Keeping nominal heating capacity at -15C 14.5 14.0 Hyper Inverter -15C Hyper Inverter 40C nominal heating capacity 14.0kW 2C Heating capacity 50C 30C Micro Inverter 8.8 0 Temperature of supply air can reach 40C in 4 minutes after start up under low temperature operation conditions (at both indoor and outdoor temperature of 2C) and can reach 50C in 8 minutes after that.
Hyper Inverter Outdoor Unit. 5.0~16.0kW. Micro SRC50ZJX-S SRC60ZJX-S FDC71VNX FDC100VN FDC125VNX FDC140VNX Blue Fin 7.1-14.0kW Due to application of blue coated fins (KS101) for the heat exchanger of the new outdoor unit, corrosion resistance has been improved compared to previous models. FDC160VSX Base heater kit (option) This kit is recommended to be used in an area where the temperature drops below 0˚C.
High efficiency Increase of heat transfer efficiency Heat transfer efficiency has improved by using high efficiency piping and by the redesign of the heat exchanger from 2 to 1 piece. FEAturEs Reduction of air flow pressure loss Pressure caused by air flow in the indoor unit is reduced by making the air outlet larger. The reduction of pressure reduces the load on the fan motor so efficiency increases.
Before starting use Heating performance Refrigerant leakage The heating performance values (kW) described in catalog are the values obtained by operating at an outdoor temperature of 7C and indoor temperature of 20C as set forth in the ISO Standards. As the heating performance decreases as the outdoor temperature drops, if the outdoor temperature is too low and the heating performance is insufficient, use other heating appliances as well.