User's Manual
22. FA TRANSPARENT FUNCTION
22.4 System Configuration
22 - 27
17
ROBOT 
CONTROLLER 
CONNECTION
18
CNC CONNECTION
19
GOT MULTI-DROP 
CONNECTION
20
MULTIPLE-GT14, GT12, 
GT11, GT10 
CONNECTION FUNCTION
21
MULTI-CHANNEL 
FUNCTION
22
FA TRANSPARENT 
FUNCTION
 When connecting the GOT and PC with Ethernet (For GT16, GT15, GT14, GT12)
*1 The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver, or other system equipment corresponding to the applicable Ethernet network 
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standards.
A cross cable is available for connecting the GOT to the Ethernet module.
*2 When connecting GT16 of the function version A to an equipment that meets the 10BASE (-T/2/5) standard, use the switching 
hub and operate in a 10Mbps/100Mbps mixed environment.
For how to check the function version, refer to the following.
GT16 User's Manual
*3 A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of 
cascades.
For the limit, contact the switching hub manufacturer.
*4 LCPU is not applicable to the bus connection.
*5 GT14 models compatible with Ethernet connection are only GT1455-QTBDE and GT1450-QLBDE.
*6 Not applicable to Setting/Monitoring tool for C Controller module.
Connection type 
dependant
Communication driver
GOT
PC
PLC
Varies according to
the connection type.
Connection cable
PLC GOT
Connection cable
*1
Maximum 
segment 
length
*3
Personal 
computer
Number of 
connectable 
equipment
Connection type Model Interface Cable model Software
For the system configuration 
between
the GOT and PLC, refer to 
the following.
 BUS 
CONNECTION
*4
 DIRECT 
CONNECTION TO CPU
*6
 COMPUTER LINK 
CONNECTION
*6
*2 *5
- (Built into GOT)
Twisted pair cable
• 10BASE-T
Shielded twisted pair cable 
(STP) or unshielded 
twisted pair cable (UTP): 
Category 3, 4, and 5
• 100BASE-TX
Shielded twisted pair cable 
(STP): 
Category 5 and 5e
100m
GX Works2
Setting/
Monitoring tool
for C Controller
module
1 personal
computer
for 1 GOT
GT15-J71E71-100