User's Manual
19. GOT MULTI-DROP CONNECTION
19.6 Setting of Serial Multi-Drop Connection Unit
19 - 27
17
ROBOT 
CONTROLLER 
CONNECTION
18
CNC CONNECTION
19
GOT MULTI-DROP 
CONNECTION
20
MULTIPLE-GT14, GT12, 
GT11, GT10 
CONNECTION FUNCTION
21
MULTI-CHANNEL 
FUNCTION
22
FA TRANSPARENT 
FUNCTION
 Exporting/Importing the communication 
setting contents
(1)  Export
1. After determining the storage location as necessary, 
name the file and save it.
The file format is [*.ini] (fixed).
(2)  Import
1. Enter the name of the file previously saved and open 
the file.
The file format is [*.ini] (fixed).
 Communication detail settings
Make the settings according to the usage environment.
(3) For the connection with GOT
(4) For the connected equipment
Set the communication detail settings of the driver for 
controllers according to the connection type.
 Refer to each chapter.
Item Description Range
Transmission Speed
Set this item when change the 
transmission speed used for 
communication with the connected 
equipment.
(Default: 115200bps)
4800bps, 
9600bps, 
19200bps, 
38400bps, 
57600bps, 
115200bps
Retry
Set the number of retries to be 
performed when a communication 
timeout occurs.
When receiving no response after 
retries, the communication times 
out.
(Default: 0time)
0 to 5times
Timeout Time
Set the time period for a 
communication to time out.
(Default: 3sec)
3 to 30sec
Delay Time
Set this item to adjust the 
transmission timing of the 
communication request from the 
GOT.
(Default: 0ms)
0 to 300 ms