18. CNC CONNECTION
18.4 GOT Side Settings
18 - 15
17
ROBOT 
CONTROLLER 
CONNECTION
18
CNC CONNECTION
19
GOT MULTI-DROP 
CONNECTION
20
MULTIPLE-GT14, GT12, 
GT11, GT10 
CONNECTION FUNCTION
21
MULTI-CHANNEL 
FUNCTION
22
FA TRANSPARENT 
FUNCTION
(3) Transmission baudrate setting switch
(4) Condition setting switches
POINTPOINTPOINT
(1) Switch setting example
For the switch setting example, refer to the 
following.
18.5.2 CC-Link (ID) connection
(2) When the switch setting is changed
When changing the switch setting after mounting 
the GT15-75J61BT13-Z type CC-Link 
communication unit to the GOT, reset the GOT.
Transmission 
baudrate setting 
switch
Description Set value
Specify the transmission speed.
(Default: 0)
0: 156kbps
1: 625kbps
2: 2.5Mbps
3: 5Mbps
4: 10Mbps
Condition 
setting 
switches
Setting 
switch
Description Set value
SW1
Specify input data status of the 
data link error station.
(Default: OFF)
OFF: Cleared
ON: Held
SW2
Specify the number of stations 
occupied.
(Default: OFF)
OFF: 1 station
ON: 4 stations
0
9
8
7
6
5
4
3
2
1
21
ON