User's Manual
13. CC-Link CONNECTION (INTELLIGENT DEVICE STATION)
13.4 PLC Side Setting
13 - 31
9
MELSECNET/H 
CONNECTION (PLC 
TO PLC NETWORK)
10
MELSECNET/10 
CONNECTION (PLC 
TO PLC NETWORK)
11
CC-Link IE CONTROLLER 
NETWORK 
CONNECTION
12
CC-Link IE FIELD 
NETWORK 
CONNECTION
13
CC-Link CONNECTION 
(INTELLIGENT DEVICE 
STATION)
14
CC-Link 
CONNECTION 
(Via G4)
15
INVERTER 
CONNECTION
16
SERVO AMPLIFIER 
CONNECTION
 [Controller Setting] of GT Designer3
(1) When MODEL GT15-J61BT13 CC-Link 
communication unit is used
(2) When MODEL GT15-75J61BT13-Z CC-Link 
communication unit is used
POINTPOINTPOINT
[Controller Setting] of GT Designer3
For the setting method of [Controller Setting] of GT
Designer3, refer to the following.
13.3.1 Setting communication interface 
(Communication settings)
 Setting of the CC-Link communication unit 
(Only when MODEL GT15-75J61BT13-Z 
CC-Link communication unit is used)
POINTPOINTPOINT
Setting of the CC-Link communication unit
For the setting method of the CC-Link communication
unit, refer to the following.
13.3.3 Switch setting (Only when MODEL 
GT15-75J61BT13-Z CC-Link communication 
unit is used)
13.4.7 Connecting to CC-Link module 
(A Series)
This section describes the settings of the GOT and CC-
Link module (A Series) in the following case of system 
configuration.
POINTPOINTPOINT
CC-Link module (A Series)
For details of the CC-Link module (A Series), refer to
the following manual.
Control & Communication Link System Master/
Local Module Type AJ61BT11/A1SJ61BT11 
User's Manual
 System configuration
*1 The CC-Link module is mounted on the base unit slot 0.
The Start I/O No. of the CC-Link module is set to "0"
Item Set value
Station No. 1: Station No.1
Transmission Rate 0: Online 156kbps
Mode Ver.1: Remote net (Ver.1 mode)
Expanded Cyclic Single (Use default value)
Number of stations occupied
1 Station
Input for Error Station 0: Clear
Retry 3times (Use default value)
Timeout Time 3sec (Use default value)
Delay Time 0ms (Use default value)
Item Set value (Use default value)
Retry 3times
Timeout Time 3sec
Item Set value
Mode setting switch 0: Online (fixed)
Station number setting switch 1: Station No.1
Transmission baudrate setting switch 0: 156kbps
Condition 
setting 
switches
SW1
(Input data status of the data 
link error station)
OFF: Cleared
SW2 (Number of occupied 
stations)
OFF: 1 station
*1
<CC-Link module> 
 (Use the default value for settings other than the following.)
<GOT> 
(Use the default value for settings other
 than the following.)
Station type : Master station
All connect count
: 1
Mode setting
: Remote net mode
Station No.
: Station No.0
Module mode
: Intelligent mode
Transmission speed
: 156kbps
Station type
: Intelligent device
 station
Station No.
: Station No.1
Number of station occupied : Exclusive station 1
Transmission 
speed
: 156kbps
■ [Controller Setting] of GT Designer3
■ Setting of the CC-Link communication unit
■ Settings of CC-Link module (A Series)
■ Sequence program