13. CC-Link CONNECTION (INTELLIGENT DEVICE STATION)
13.4 PLC Side Setting
13 - 13
9
MELSECNET/H 
CONNECTION (PLC 
TO PLC NETWORK)
10
MELSECNET/10 
CONNECTION (PLC 
TO PLC NETWORK)
11
CC-Link IE CONTROLLER 
NETWORK 
CONNECTION
12
CC-Link IE FIELD 
NETWORK 
CONNECTION
13
CC-Link CONNECTION 
(INTELLIGENT DEVICE 
STATION)
14
CC-Link 
CONNECTION 
(Via G4)
15
INVERTER 
CONNECTION
16
SERVO AMPLIFIER 
CONNECTION
13.4.1 Connecting to CC-Link module 
(Q Series) with Ver.1 
compatible
This section describes the settings of the GOT and the CC-
Link module (Q Series) with Ver.1 compatible in the 
following system configuration.
POINTPOINTPOINT
CC-Link module (Q Series)
For details of the CC-Link module (Q Series), refer to
the following manual.
CC-Link System Master/Local Module User's 
Manual QJ61BT11N
 System configuration
*1 The CC-Link module is mounted on the base unit slot 0.
The Start I/O No. of the CC-Link module is set to "0"
 Switch setting of CC-Link module (Q Series)
Set the station number setting switch, transmission 
speed / mode setting switch.
(1) Station number setting switch
: Necessary  : As necessary  : Not necessary
(2) Transmission rate/mode setting switch
: Necessary  : As necessary  : Not necessary
*1 Specify the same transmission speed as that of the GOT.
POINTPOINTPOINT
When the switch setting is changed
Turn the PLC CPU OFF then ON again, or reset the
PLC CPU.
<CC-Link module>
*1
Type : Master station
Station No. : Station No.0
Mode : Remote net (Ver.1 mode)
All connect count : 1
Transmission speed : 156kbps
<GOT> 
(Use the default value for settings other 
 than the following.)
Station type : Intelligent device 
station
Station No. : Station No.1
Number of 
stations occupied
: Exclusive station 1
Transmission speed : 156kbps
(Use the default value for the settings other than the following.)
■ [Controller Setting] of GT Designer3
■ Setting of the CC-Link communication unit
■ Switch setting of CC-Link module (Q Series)
■ [Network parameter] of GX Developer
Station number 
setting switch
Description Set value
Setting necessity at 
GOT connection
Station number 
setting
(master station)
0 (fixed)
Transmission 
rate/mode setting 
switch
Description Set value
Setting necessity at 
GOT connection
Transmission 
rate/
mode setting
(Online: 
156kbps)
*1
0
(1)
(2)
QJ61BT11, QJ61BT11N
0
5
0
5
0
8
1
2
7
6
5
4
3
STATION 
NO.
X10
X1
MODE
QJ61BT11N
RUN
ERR. 
SD 
MST
L RUN
L ERR.
RD
S MST
NC
DA
DB
NC
SLD
DG
(FG)
C
4
MODE