User's Manual
12. CC-Link IE FIELD NETWORK CONNECTION
12.3 GOT side settings
12 - 9
9
MELSECNET/H 
CONNECTION (PLC 
TO PLC NETWORK)
10
MELSECNET/10 
CONNECTION (PLC 
TO PLC NETWORK)
11
CC-Link IE CONTROLLER 
NETWORK 
CONNECTION
12
CC-Link IE FIELD 
NETWORK 
CONNECTION
13
CC-Link CONNECTION 
(INTELLIGENT DEVICE 
STATION)
14
CC-Link 
CONNECTION 
(Via G4)
15
INVERTER 
CONNECTION
16
SERVO AMPLIFIER 
CONNECTION
*1 For details, refer to the following manual.
CC-Link IE Field Network Master/Local Module 
User's Manual
*2 This range is effective when collecting a large amount of 
data (such as logging and recipe function) on other than the 
monitor screen.
However, the range may affect the sequence scan time 
when connecting to Q00UJ/Q00U/Q01U/Q02UCPU.
If you want to avoid the influence on the sequence scan time, 
do not set [High].
(This setting hardly affects QCPUs other than the above.)
*3 Set this range if you want to avoid the influence on the 
sequence scan time further than the [Normal] setting when 
connecting to Q00UJ/Q00U/Q01U/Q02UCPU.
However, the monitor speed may be reduced.
POINTPOINTPOINT
(1) Switch setting example
For the switch setting example, refer to the 
following.
12.4 PLC Side Setting
(2) Communication interface setting by Utility
The communication interface setting can be 
changed on the Utility's [Communication Settings] 
after writing [Communication Settings] of project 
data.
For details on the Utility, refer to the following 
manual.
GT  User’s Manual
(3) Precedence in communication settings
When settings are made by GT Designer3 or the 
Utility, the latest setting is effective.
(4) Network type
Be sure to set the same network types for the CPU 
side and the GOT side. If the network types of the 
CPU side and the GOT side are different, an error 
is displayed in the system alarm of the GOT side.
12.3.3 Routing parameter setting
Up to 64 [Transfer Network No.]s can be set.
However, the same transfer network number cannot be set 
twice or more (multiple times).
Therefore, the one that can access to other station from the 
request source host GOT is 64 kinds of [Transfer Network 
No.]s.
POINTPOINTPOINT
Routing parameter setting
When communicating within the host network, routing
parameter setting is unnecessary.
For details of routing parameters, refer to the following
manual.
CC-Link IE Field Network 
Reference Manual
*1 Basic model QCPU and the QSCPU are not included.
POINTPOINTPOINT
(1) Routing parameter setting of relay station
Routing parameter setting is also necessary for 
the relay station.
For the setting, refer to the following.
12.4 PLC Side Setting
(2) Parameter reflection function of MELSOFT Navigator
(a) The color of the cells for the items which are 
reflected to GT Designer3 from MELSOFT 
Navigator changes to green. Set items, which 
are displayed in green cells, from the 
MELSOFT Navigator.
(b) When the settings of Transfer network No., 
Relay network No. or Relay station No. are 
reflected to the parameter from the MELSOFT 
Navigator, those settings are added. Items set 
in advance are not deleted. However, if the 
target network No. overlaps, the item set in 
advance is overwritten.
(c) The routing information is used manually by 
the user when the data is created. Therefore, 
after changing the network configuration by 
MELSOFT Navigator, create a routing 
information again. For details of the creation 
of the routing information, refer to the 
MELSOFT Navigator help.
Item Range
Transfer Network No. 1 to 239
Relay Network No. 1 to 239
Relay Station 
No.
MELSEC-Q (Universal model)
Q170MCPU C Controller Module
0 to 120