User's Manual
10 - 22
10. MELSECNET/10 CONNECTION (PLC TO PLC NETWORK)
10.4 PLC Side Setting
 Switch setting of MELSECNET/10 network 
module
Set for each setting switch.
(1) Network number setting switch
: Necessary  : As necessary  : Not necessary
*1 Specify the same network No. as that of the GOT.
*2 Do not specify a number between 240 and 255.
(2) Group number setting switch
: Necessary  : As necessary  : Not necessary
(3) Station number setting switch
: Necessary  : As necessary  : Not necessary
*3 Do not set the same station No. as that of the GOT.
(4) LED indication select switch
: Necessary  : As necessary  : Not necessary
(6)
(4)
(1)
(2)
(3)
(5)
A1SJ71LP21
A1SJ71LP21
A1SJ71LP21
3
2
0
5
9
4
8
7
6
1
3
2
0
5
9
4
8
7
6
1
3
2
0
5
9
4
8
7
6
1
3
2
0
5
9
4
8
7
6
1
3
2
0
5
9
4
8
7
6
1
3
2
0
5
9
4
8
7
6
1
E
6
D
5
C
4
B
3
A
2
9
1
8
0
F
7
SW 
1 
2 
3 
4 
5 
6 
7 
8 
OFF 
PC 
N.ST 
PRM
ON 
REM. 
MNG 
D.PRM
ST,SIZE 
8,16,32,64 
LB/LW SIZE 
2,4,6,8k
CRC 
OVER 
AB. IF 
TIME 
DATA 
UNDER 
SD 
RD
 PW 
PC 
REM. 
SWE. 
M/S.E. 
PRM E. 
R.E. 
CPU R/W
RUN 
MNG 
S.MNG 
DUAL 
D.LINK 
T.PAS. 
F.E.
E
R
R
O
R
LR
DISPLAY
(F.L) (R.L.)
NETWORK
NO.
X100 
X10 
X1
OFF ON
IN
FRONT SIDE
OUT
SW 
1 
2 
3 
4 
5 
6 
7 
8 
GR.NO.
ST.NO.
X10
X1
MODE
MODE 
(6)
(4)
(1)
(2)
(3)
(5)
A1SJ71BR11
A1SJ71BR11
A1SJ71BR11
3
2
0
5
8
7
3
2
0
5
8
7
3
2
0
5
8
7
3
2
0
5
8
7
3
2
0
5
8
7
3
2
0
5
8
7
D
5
C
4
B
3
9
1
8
0
F
7
SW 
1 
2 
3 
4 
5 
6 
7 
8 
OFF 
PC 
N.ST 
PRM
ON 
REM. 
MNG 
D.PRM
ST,SIZE 
8,16,32,64 
LB/LW SIZE 
2,4,6,8k
CRC 
OVER 
AB. IF 
TIME 
DATA 
UNDER 
SD 
RD
 PW 
PC 
REM. 
SWE. 
M/S.E. 
PRM E. 
CPU R/W
 RUN 
MNG 
S.MNG 
D.LINK 
T.PAS.
LR
DISPLAY
NETWORK
NO.
X100 
X10 
X1
OFF ON
SW 
1 
2 
3 
4 
5 
6 
7 
8 
GR.NO.
ST.NO.
X10
X1
MODE
MODE 
0 : ONLINE(A,R) 
2 : OFFLINE 
(1)
(2)
(6)
(3)
(5)
AJ71LP21
NETWORK NO. 
X100
X10
X1
GROUP NO.
STATION NO. 
X10
X1
MODE
0: ONLINE(A.R) 
2: OFFLINE
OFF
PC REMOTE
N.ST MNG
PRM D.PRM
STATION SIZE 
(8.16 .32.64)
LB/ LW SIZE 
(2.4.6 .8K)
OFFON ON SW
1 
2 
3 
4 
5 
6 
7 
8
A
J71LP21
RUN - 
PC - 
REMOTE - 
DUAL - 
SW.E - 
M/S.E - 
PRM.E - 
CRC - 
OVER - 
AB.IF - 
TIME - 
DATA - 
UNDER - 
LOOP - 
SD - 
RD -
- POWER 
- MNG 
- S.MNG 
- D.LINK 
- T.PASS 
- EX.POWER 
- CPUR/W 
- CRC 
- OVER 
- AB.IF 
- TIME 
- DATA 
- UNDER 
- LOOP 
- SD 
- RD
F.LOOP R.LOOP
10
1
100
E 
R 
R 
O 
R
E 
R 
R 
O 
R
OUT
IN
FRONT SIDE
E 
R 
R 
O 
R
(1)
(2)
(6)
(3)
(5)
AJ71BR11
NETWORK NO. 
X100
X10
X1
GROUP NO.
STATION NO. 
X10
X1
MODE
0: ONLINE(A.R) 
2: OFFLINE
OFF
PC REMOTE
N.ST MNG
PRM
D.PRM
STATION SIZE 
(8.16.32.64)
LB/LW SIZE 
(2.4.6.8K)
OFFON ON SW
1 
2 
3 
4 
5 
6 
7 
8
A
J71BR11
RUN - 
PC - 
REMOTE - 
SW.E - 
M/S.E - 
PRM.E - 
CRC - 
OVER - 
AB.IF - 
TIME - 
DATA - 
UNDER - 
SD - 
RD -
- POWER 
- MNG 
- S.MNG 
- D.LINK 
- T.PASS 
- 
- CPUR/W
10 1
100
E 
R 
R 
O 
R
0 : ONLINE(A,R) 
2 : OFFLINE 
E
R
R
O
R
Network number 
setting switch
Description
Set 
value
Setting 
necessity at 
GOT 
connection
Network 
No. setting 
(Network 
No.1)
*1*2
1
Group number 
setting switch
Description
Set 
value
Setting 
necessity at 
GOT 
connection
Group No. 
setting 
(No group 
setting)
0
(fixed)
Station number setting switch Description
Set 
value
Setting 
necessity at 
GOT 
connection
Station number 
setting 
(Station No.1)
*3
1
LED indication select switch Description
Set 
value
Setting 
necessity at 
GOT 
connection
LED indication 
select
L (F.L.)
3
2
0
5
9
4
8
7
6
1
3
2
0
5
9
4
8
7
6
1
3
2
0
5
9
4
8
7
6
1
NETWORK NO. 
X100 
X10 
X1
3
2
0
5
9
4
8
7
6
1
GROUP.NO.
3
2
0
5
9
4
8
7
6
1
3
2
0
5
9
4
8
7
6
1
STATION.NO.
X10
X1
LR
DISPLAY
(F.L) (R.L.)