User's Manual
9 - 12
9. MELSECNET/H CONNECTION (PLC TO PLC NETWORK)
9.4 PLC Side Settings
(1) Station number setting switch
: Necessary  : As necessary  : Not necessary
*1 Do not set the same station No. as that of the GOT.
(2) Mode setting switch
: Necessary  : As necessary  : Not necessary
*2 Set the same mode setting and transmission speed as those 
of the GOT.
POINTPOINTPOINT
When the switch setting has been changed
Turn the PLC CPU OFF then ON again, or reset the
PLC CPU.
9.4.3 Parameter setting
 Connecting to MELSEC-Q or QS series
(1) [Network parameter] of GX Developer
(a) Network parameter
: Necessary  : As necessary  : Not necessary
*1 When using Q170MCPU, set it according to the system 
configuration.
*2 Specify the same network No. as that of the GOT.
*3 Set the same mode setting as that of the GOT.
*4 Set it when the MELSECNET/H network module is used in 
the redundant QnPRHCPU system.
Station number setting 
switch
Description
Set 
value
Setting 
necessity at 
GOT 
connection
Station number 
setting
(Station No.1)
*1
1
Mode setting switch Description
Set 
value
Setting 
necessity at 
GOT 
connection
Mode setting
(Online: 
10Mbps)
*2
0
0
5
9
4
8
3
7
2
6
1
0
5
9
4
8
3
7
2
6
1
STATION NO.
X10
X1
MODE
0
8
F
7
E
6
D
5
C
4
B
A
3
2
9
1
Item Set value
Setting 
necessity at 
GOT connection
Network type
MNET/H mode
(Control station) 
(fixed)
Starting I/O No.
*1
0000H
Network No.
*2
1
Total stations 2
Group No. 0 (fixed)
Mode
*3
Online
Network range assignment Refer to (b).
Refresh parameters
(Use default value)
Interrupt settings
Control station return setting
Redundant settings
*4
Interlink transmission 
parameters
Routing parameters Refer to (c).