User's Manual
3 - 10
3. ACCESS RANGE FOR MONITORING
3.1 Access Range for Monitoring Stations on Network Systems
Example 4: When using CPU direct connection or computer link connection
• Monitor accessible range of devices (other than B or W) of other stations or other networks 
Specify the accessing network No. or station as shown in the following table.
(1) To monitor B or W of the connected station (host station) assigned with a network parameter, specify the host 
station.
(2) To monitor another station (other than B or W) or another network, specify the station (network No. and station 
No.).
*1 When monitoring the data link system, designate the network No. as 0.
POINTPOINTPOINT
Monitoring link device B or W
For monitoring devices B and W that are allocated by the link parameter, use the host device number even when 
designating devices allocated to another station.
Otherwise, the display speed will be reduced.
Station to be
accessed
Station 
connected to GOT
Network No.1 Network No.2 Data link system
QnA (1-1) AnA (1-2) QnA (1-3) AnU (2-1) QnA (2-2) AnU (2-3) AnU (2-4) QnA (M) QnA (L1) AnA (L2)
Q (Q mode) (1-1)
Host
Other (1-2) Other (1-3) Other (2-1) Other (2-2) Other (2-3)
Other (2-4)
Other (1-3)
or
Other (2-2)
── ──
AnA (1-2)
── Host ── ── ── ── ── ── ── ──
QnA
(1-3)
(2-2)
Other (1-1)
── Host
Other (2-1)
Host
Other (2-3)
Other (2-4) Host ──
*1
Other (0-2)
(M)
AnU (2-1)
── ── ── Host ──
Other (2-3)
Other (2-4) ── ── ──
AnU (2-3)
── ── ──
Other (2-1)
── Host Other (2-4) ── ── ──
AnU (2-4)
── ── ──
Other (2-1)
──
Other (2-3)
Host ── ── ──
QnA (L1)
── ── ── ── ── ── ── ── Host ──
AnA (L2)
── ── ── ── ── ── ── ── ── Host
How to 
read the 
table
Upper line:  Accessibility
: Accessible
: Not accessible
Lower line:  Network settings
Host
Other (Network No. - Station number)
Control station
AnU
(2-4)
QnA
(1-3)
(2-2)
(M)
Network No.2
AnU
(2-1)
Network No.1
AnA
(1-2)
QnA
(L1)
AnA
(L2)
Data link
system
Control station
Q(Q mode)
(1-1)
AnU
(2-3)