Car Amplifier User Manual
Table Of Contents
- Safety Instructions
- COMPLIANCE WITH EC DIRECTIVES
- CONFORMANCE WITH UL/C-UL STANDARD
- <
> - CONTENTS
- Optional Servo Motor Instruction Manual CONTENTS
- 1. FUNCTIONS AND CONFIGURATION
- 2. INSTALLATION
- 3. SIGNALS AND WIRING
- 3.1 Standard connection example
- 3.2 Internal connection diagram of servo amplifier
- 3.3 I/O signals
- 3.4 Detailed description of the signals
- 3.5 Alarm occurrence timing chart
- 3.6 Interfaces
- 3.7 Input power supply circuit
- 3.8 Connection of servo amplifier and servo motor
- 3.9 Servo motor with electromagnetic brake
- 3.10 Grounding
- 3.11 Servo amplifier terminal block (TE2) wiring method
- 3.12 Instructions for the 3M connector
- 3.13 Power line circuit of the MR-J2S-11KA to MR-J2S-22KA
- 4. OPERATION
- 5. PARAMETERS
- 6. DISPLAY AND OPERATION
- 7. GENERAL GAIN ADJUSTMENT
- 8. SPECIAL ADJUSTMENT FUNCTIONS
- 9. INSPECTION
- 10. TROUBLESHOOTING
- 11. OUTLINE DIMENSION DRAWINGS
- 12. CHARACTERISTICS
- 13. OPTIONS AND AUXILIARY EQUIPMENT
- 13.1 Options
- 13.1.1 Regenerative brake options
- 13.1.2 Brake unit
- 13.1.3 Power regeneration converter
- 13.1.4 External dynamic brake
- 13.1.5 Cables and connectors
- 13.1.6 Junction terminal block (MR-TB20)
- 13.1.7 Maintenance junction card (MR-J2CN3TM)
- 13.1.8 Battery (MR-BAT, A6BAT)
- 13.1.9 MR Configurator (Servo configurations software)
- 13.1.10 Power regeneration common converter
- 13.1.11 Heat sink outside mounting attachment (MR-JACN)
- 13.2 Auxiliary equipment
- 13.2.1 Recommended wires
- 13.2.2 No-fuse breakers, fuses, magnetic contactors
- 13.2.3 Power factor improving reactors
- 13.2.4 Power factor improving DC reactors
- 13.2.5 Relays
- 13.2.6 Surge absorbers
- 13.2.7 Noise reduction techniques
- 13.2.8 Leakage current breaker
- 13.2.9 EMC filter
- 13.2.10 Setting potentiometers for analog inputs
- 13.1 Options
- 14. COMMUNICATION FUNCTIONS
- 14.1 Configuration
- 14.2 Communication specifications
- 14.3 Protocol
- 14.4 Character codes
- 14.5 Error codes
- 14.6 Checksum
- 14.7 Time-out operation
- 14.8 Retry operation
- 14.9 Initialization
- 14.10 Communication procedure example
- 14.11 Command and data No. list
- 14.12 Detailed explanations of commands
- 14.12.1 Data processing
- 14.12.2 Status display
- 14.12.3 Parameter
- 14.12.4 External I/O pin statuses (DIO diagnosis)
- 14.12.5 Disable/enable of external I/O signals (DIO)
- 14.12.6 External input signal ON/OFF (test operation)
- 14.12.7 Test operation mode
- 14.12.8 Output signal pin ON/OFF output signal (DO) forced output
- 14.12.9 Alarm history
- 14.12.10 Current alarm
- 14.12.11 Other commands
- 15. ABSOLUTE POSITION DETECTION SYSTEM
- 15.1 Outline
- 15.2 Specifications
- 15.3 Battery installation procedure
- 15.4 Standard connection diagram
- 15.5 Signal explanation
- 15.6 Startup procedure
- 15.7 Absolute position data transfer protocol
- 15.8 Examples of use
- 15.9 Confirmation of absolute position detection data
- 15.10 Absolute position data transfer errors
- Appendix
- REVISIONS

13 - 12
13. OPTIONS AND AUXILIARY EQUIPMENT
(b) Resistor unit (FR-BR)
[Unit : mm(in)]
33 (1.299)
204
(8.031)
40 (1.575)
K
(F)
(F)
BA 1 (0.039)
C 5
(0.197)
2- D
AA 5 (0.197)
EE
(E)
A 5 (0.197)
EE
(E)
(Note)
Control circuit
terminals
Main circuit
terminals
FR-BR-55K
Two eye bolts are provided
(as shown below).
Eye bolt
BB 3 (0.118)
B 5 (0.197)
Note. Ventilation ports are provided in both side faces and top face. The bottom face is open.
Resistor
Unit
Model
AAABBABBC D EEEK F
Approx.
Mass
[kg(Ib)]
FR-BR-
15K
170
(6.693)
100
(3.937)
450
(17.717)
432
(17.008)
410
(16.142)
220
(8.661)
6
(0.236)
35
(1.378)
6
(0.236)
1.6
(0.063)
20
(0.787)
15
(66.139)
FR-BR-
30K
340
(11.389)
270
(10.63)
600
(23.622)
582
(22.913)
560
(22.047)
220
(8.661)
10
(0.394)
35
(1.378)
10
(0.394)
2
(0.079)
20
(0.787)
30
(33.069)
FR-BR-
55K
480
(18.898)
410
(16.142)
700
(27.559)
670
(26.378)
620
(24.409)
450
(17.717)
12
(0.472)
35
(1.378)
12
(0.472)
3.2
(0.126)
40
(1.575)
70
(154.323)
13.1.3 Power regeneration converter
When using the power regeneration converter, set "01
" in parameter No.0.
(1) Selection
The converters can continuously return 75% of the nominal regenerative power. They are applied to
the servo amplifiers of the MR-J2S-500A to MR-J2S-22KA.
Power
regeneration
converter
Nominal
Regenerative
Power (kW)
Servo Amplifier
FR-RC-15 15
MR-J2S-500A
MR-J2S-700A
FR-RC-30 30
MR-J2S-11KA
MR-J2S-15KA
FR-RC-55K 55
MR-J2S-22KA
05075100150
500
300
200
100
50
30
20
Continuous energization time [sec]
Nominal regenerative power (%)