System information
57
4.2.37. Oscmode (Display Screen Mode)
Function: Screen mode in input signal of the input boards (VC-B20KA / VC-B20KV / VC-B50KA /
VC-B50KV) setting. The execution result is saved in display memory by Regdisp command
execution. It executes after UP command receiving.
Effective inputs: S.ANALOG, S.DIGITAL, COMPOSITE, Y/C
Format: ID Oscmode [ _ Mode ]
Screen mode
0NORMAL
1TRIMMING
2FULL
Mode
Omitted Current setting status display
Response: ID Oscmode _ mode
Current screen mode
0NORMAL
1TRIMMING
2FULL
?00 Invalid parameter
mode
?01 Execution failure
4.2.38. Out (Digital Out)
Function: Digital out setting to select the input memory number to be output from the digital output
terminal of the input board (VC-B20KA / VC-B50KA). It is invalid when input memory of
XL20U main unit is selected as designate input memory. The execution result is saved in
display memory by Regdisp command execution.
Effective inputs: S.ANALOG, S.DIGITAL, COMPOSITE, Y/C
Format: ID Out [ _ MemNo]
Digital out setting
0OFF
1 – 128 Input memory number
129 SCREEN
MemNo
Omitted Current setting value display
Response: ID Out _ memno
Current digital out setting
0OFF
1 – 128 Input memory number
129 SCREEN
?00 Invalid parameter
memNo
?01 Execution failure