System information

REV 4.0.
54
4.2.31. Ivsize (V size)
Function: Vertical lines setting in input signal. The execution result is saved in input memory by
Reginp command execution. It executes after UP command receiving. The values of Ovcrp,
Ovcsize, Ovst and Ovsize are re-calculated by this command.
Effective models and inputs: ANALOG and DIGITAL of model group A, B
S.ANALOG, S.DIGITAL, COMPOSITE, Y/C of all models
Format: ID Ivsize [ _ Size ]
Effective vertical size setting value
350 – 1050 Effective vertical size setting
value
ANALOG and DIGITAL
of model group A, B
8 – 1300 Effective vertical size setting
value
S.ANALOG, S.DIGITAL
COMPOSITE, Y/C
Size
Omitted Current setting value display
Response: ID Ivsize _ size
Current effective vertical size setting value
350 – 1050 Effective vertical size setting
value
ANALOG and DIGITAL
of model group A, B
8 – 1300 Effective vertical size setting
value
S.ANALOG, S.DIGITAL
COMPOSITE, Y/C
?00 Invalid parameter
size
?01 Execution failure
4.2.32. Ivst (V start position)
Function: Vertical start position setting in input signal. The execution result is saved in input
memory by Reginp command execution. It executes after UP command receiving. The sum
of Ivst and Ivsize setting values may be automatically changed not to over the measured line
number of the input signal.
Format: ID Ivst [ _ Start ]
Effective vertical start position setting value
0 – 50 ANALOG and DIGITAL of model group C
0 – 500 ANALOG and DIGITAL of model group A, B
0 – 1200 S.ANALOG, S.DIGITAL, COMPOSITE, Y/C
Start
Omitted Current setting value display
Response: ID Ivst _ start
Current effective vertical start position setting value
0 – 50 ANALOG and DIGITAL of model group C
0 – 500 ANALOG and DIGITAL of model group A, B
0 – 1200 S.ANALOG, S.DIGITAL, COMPOSITE, Y/C
?00 Invalid parameter
start
?01 Execution failure