System information
REV 4.0.
52
4.2.25. Isig (Input SignalType)
Function: Signal type setting to select (RGB, YcbCr or YPbPr). This command is an exclusive
command for the input board (VC-B20KA / VC-B50KA). The execution result is saved in
input memory by Reginp command execution. It executes after UP command receiving.
Effective inputs: S.ANALOG, S.DIGITAL
Format: ID Isig [ _ Mode ]
Input signal
0RGB
1 YPbPr
2 YcbCr(VC-B50KA)
Mode
Omitted Current setting status display
Response: ID Isig _ mode
Current input signal selecting
0 Input signal selecting
?00 Invalid parameter
mode
?01 Execution failure
4.2.26. Ismode (Sync Mode)
Function: Flame lock setting when input signal displaying. The execution result is saved in input
memory by Reginp command execution. It executes after UP command receiving.
Effective models and inputs: ANALOG and DIGITAL of model group A, B.
S.ANALOG, S.DIGITAL, COMPOSITE, Y/C of all models
Format: ID Ismode [ _ Mode ]
Flame lock
0 OFF (Frame rate conversion mode)
1 ON (Synchronized with input signal mode)
Mode
Omitted Current setting status display
Response: ID Ismode _ mode
Current flame lock setting
0 OFF (Frame rate conversion mode)
1 ON (Synchronized with input signal mode)
?00 Invalid parameter
mode
?01 Execution failure
4.2.27. Ispllh (PLL hold start)
Function: PLL hold start position setting in analog input signal. The execution result is saved in
input memory by Reginp command execution.
Effective models and inputs: ANALOG of model group A, B and S.ANALOG of all models
Format: ID Ispllh [ _ Start ]
PLL hold start position
-32 – 0 PLL hold start position
Start
Omitted Current setting value display
Response: ID Ispllh _ start
Current PLL hold start position and V noise mask end position
-32 – 0 Current PLL hold start position and V noise mask end
position
?00 Invalid parameter
start
?01 Execution failure