System information
REV 4.0.
50
4.2.21. Ihst (H start position)
Function: Horizontal position setting in input signal to adjust effective horizontal start position. The
execution result is saved in input memory by Reginp command execution. It executes after
UP command receiving.
Format: ID Ihst [ _ Start ]
Effective horizontal start position setting value
0 – 500 ANALOG and S.DIGITAL of model group C
0 – 1000 ANALOG and S.DIGITAL of model group A, B
0 – 1920 S.ANALOG, S.DIGITAL, COMPOSITE, Y/C
Start
Omitted Current setting value display
Response: ID Ihst _ start
Current effective horizontal start position setting value
0 – 500 ANALOG and S.DIGITAL of model group C
0 – 1000 ANALOG and S.DIGITAL of model group A, B
0 – 1920 S.ANALOG, S.DIGITAL, COMPOSITE, Y/C
?00 Invalid parameter
start
?01 Execution failure
4.2.22. Ihtotal (H total)
Function: Tracking setting in analog input signal to adjust total horizontal sampling number with
A/D converter. The execution result is saved in input memory by Reginp command
execution.
Effective inputs: ANALOG, S. ANALOG
Format: ID Ihtotal [ _ Num ]
Total horizontal sampling number (Only even number is available.)
700 – 1900 ANALOG and S.DIGITAL of model group C
700 – 2000 ANALOG and S.DIGITAL of model group A, B
700 – 2300 S.ANALOG (VC-B20KA)
700 – 2640 S.ANALOG (VC-B50KA)
Num
Omitted Current setting value display
Response: ID Ihtotal _ num
Current horizontal total sampling number
700 – 1900 ANALOG and S.DIGITAL of model group C
700 – 2000 ANALOG and S.DIGITAL of model group A, B
700 – 2300 S.ANALOG (VC-B20KA)
700 – 2640 S.ANALOG (VC-B50KA)
?00 Invalid parameter
num
?01 Execution failure