System information

49
4.2.19. Ifinv (Field Invert)
Function: Field swap setting when input signal is interlace. Use this command when the displayed
image is unnatural since the odd field and even fields are inverted. The execution result is
saved in input memory by Reginp command execution.
Effective inputs: S.ANALOG, S.DIGITAL
Format: ID Ifinv [ _ Mode ]
Field swap mode
0 Not to swap fields
1 To swap fields
Mode
Omitted Current setting value display
Response: ID Ifinv _ mode
Current field swap mode
0 Not to swap fields
1 To swap fields
?00 Invalid parameter
mode
?01 Execution failure
4.2.20. Ihsize (H size)
Function: Horizontal pixels setting in input signal to adjust effective horizontal size. The execution
result is saved in input memory by Reginp command execution. It executes after UP
command receiving.
Effective models and inputs: ANALOG and DIGITAL of model group A, B.
S.ANALOG, S.DIGITAL, COMPOSITE, Y/C of all models
Format: ID Ihsize [ _ Size ]
Effective horizontal size setting value
640 –
1400
Effective horizontal size setting value ANALOG, S.DIGITAL
of model group A, B
600 –
2000
Effective horizontal size setting value
(Only even number can be used when
composite or Y/C signal is selected.)
S.ANALOG,
S.DIGITAL,
COMPOSITE, Y/C
Size
Omitted Current setting value display
Response: ID Ihsize _ size
Current effective horizontal size setting value
640 –
1400
Current effective horizontal size
setting value
ANALOG, S.DIGITAL
of model group A, B
600 –
2000
Current effective horizontal size
setting value
(Only even number can be used when
composite or Y/C signal is selected.)
S.ANALOG,
S.DIGITAL,
COMPOSITE, Y/C
?00 Invalid parameter
size
?01 Execution failure