System information

REV 4.0.
44
4.2.8. Ibrt (Brightness)
Function: Brightness adjusting. The execution result is saved in input memory by Reginp
command execution.
Format: ID Ibrt [ _ Brt ]
Brightness setting value
-50 – 50 Brightness setting value
Brt
Omitted Current setting value display
Response: ID Ibrt _ brt
Current brightness setting value
-50 – 50 Current brightness setting value
?00 Invalid parameter
brt
?01 Execution failure
4.2.9. Iclpos (Clamp Position)
Function: Clamp pulse position setting in analog RGB input signal. The execution result is saved
in input memory by Reginp command execution.
Effective inputs: ANALOG, S.ANALOG
Format: ID Iclpos [ _ Pos ]
Clamp pulse position setting value
0 – 15 ANALOG of model group C
0 – 255
ANALOG of model group A, B and S.ANALOG of all
models
0 – 255 S.ANALOG
Pos
Omitted Current setting value display
Response: ID Iclpos _ pos
Current clamp pulse position setting value
0 – 255 Clamp pulse position setting value
?00 Invalid parameter
pos
?01 Execution failure