System information
41
4.2. Input signal adjustment commands
4.2.1. Asgain (Gain)
Function: Gain (white level) value or clamp level setting of analog RGB signal in selected input
port. The execution result is saved in input memory by Reginp command execution.
Effective inputs: ANALOG, S.ANALOG
Format: ID Asgain _ RGB [ _ Data ]
Adjusting color (R,G or B) selecting
0 Red gain fine adjusting
1 Green gain fine adjusting
2 Blue gain fine adjusting
3 Main contrast adjusting (S.ANALOG of model group C)
4 Red clamp level adjusting
5 Green clamp level adjusting
RGB
6 Blue clamp level adjusting
Gain(white level) adjusting value
0 – 127 Gain (white level) adjusting value ANALOG of model
group C
0 – 255 Gain (white level) adjusting value ANALOG of Model
group A, B and
S.ANALOG of all
models
0 – 127 Clamp level adjusting value ANALOG
0 – 255 Clamp level adjusting value S.ANALOG
256 System memory setting
Data
Omitted Current setting value display
Response: ID Asgain_ rgb [ _ data ]
R,G or B selecting
0 Red gain fine adjusting
1 Green gain fine adjusting
2 Blue gain fine adjusting
3 Main contrast adjusting (S.ANALOG of model group C)
4 Red clamp level adjusting
5 Green clamp level adjusting
6 Blue clamp level adjusting
?00 Invalid parameter
rgb
?01 Execution failure
Current gain value of the color designated in rgb.
If 255(system memory setting value) is designated as the gain value, the
system memory setting value will be returned in the next value
operating.
0 – 127 Gain (white level) adjusting value ANALOG of model
group C
0 – 255 Gain (white level) adjusting value ANALOG of model
group A, B and
S.ANALOG of all
models
0 – 127 Clamp level adjusting value ANALOG
0 – 255 Clamp level adjusting value S.ANALOG
data
Omitted It is omitted when rgb is ” ?00 ” or ” ?01 ”.