System information
REV 4.0.
36
4.1.35. Shpos (H position)
Function: Offset value of horizontal position setting. The pending commands are updated when
this command is executed. This command is invalid when display mode (Sdisp command) is
set without pixel superimposition. The execution result is saved in system memory by save
command execution.
Effective inputs: S.ANALOG, S.DIGITAL, COMPOSITE, Y/C
Format: ID Shpos [ _ Offset ]
Offset value of horizontal position
-16 – 16 Offset value of horizontal position
Offset
Omitted Current setting value display
Response: ID Shpos _ offset
Current offset value of horizontal position
-16 – 16 Offset value of horizontal position
?00 Invalid parameter
offset
?01 Execution failure
4.1.36. Shsize (H size)
Function: Offset value of horizontal size setting. The pending commands are updated when this
command is executed. This command is invalid when display mode (Sdisp command) is set
without pixel superimposition. The execution result is saved in system memory by save
command execution.
Effective inputs: S.ANALOG, S.DIGITAL, COMPOSITE, Y/C
Format: ID Shsize [ _ Offset ]
Offset value of horizontal size
-16 – 16 Offset value of horizontal size
Offset
Omitted Current setting value display
Response: ID Shsize _ offset
Current offset value of horizontal size
-16 – 16 Offset value of horizontal size
?00 Invalid parameter
offset
?01 Execution failure
4.1.37. Slampout (Lamp out mode)
Function: Lamp out mode setting. To select lamp burnout operation mode or normal mode when
lamp burnout is detected. If the input board is not installed in model group A and B, display
shuts down regardless of the setting. The execution result is saved in system memory by
save command execution.
Format: ID Slampout [ _ Mode]
Operation mode
0 Normal mode (not lamp burnout mode)
1 Lamp burnout operation mode
Mode
Omitted Current setting value display
Response: ID Slampout _ mode
Operation mode
0 Normal mode (not lamp burnout mode)
1 Lamp burnout operation mode
?00 Invalid parameter
mode
?01 Execution failure
The lamp burnout operation mode is the status that does not become stand-by state when the
lamp is burnout. In this mode, digital out and commands are available.