4.1.30. SetW (White Balance)
Function: White balance adjusting in Current white balance pattern (LOW, MIDDLE or HIGH). This
command is invalid when auto luminance control function (SALC command) is set STOP or
RUN. The execution result is saved in system memory by save command execution.
Format: ID SetW _ RGB [ _ Data ]
Color (R, G or B) selecting in white
0Red
1 Green
RGB
2Blue
White balance adjusting value
0 – 1000 White balance adjusting value
Data
Omitted Current setting value display
Response: ID SetW _ rgb [ _ data ]
Color (R, G or B) selecting in white
0Red
1 Green
2Blue
?00 Invalid parameter
rgb
?01 Execution failure
Current white balance adjusting value designated in rgb
0 – 1000 White balance adjusting value
data
Omitted It is omitted when rgb is “?00” or “?01”.
4.1.31. Sfilter (Filter Timer Read / Timer Reset)
Function: To get and reset filter timer value. “Check Filter” warning is non-displayed temporary by
the timer value resetting. Status is automatically saved at shut down. This command is an
exclusive command for front access model.
Format: ID Sfilter [ _ Flag ]
Reset execution flag
0 Resetting of filter timer value
Flag
Omitted Current filter timer value display
Response: ID Sfilter _ flag
Execution status
0 Normal end (Filter timer has been reset)
0–30000 Filter timer value
?00 Invalid parameter
flag
?01 Execution failure