System information

REV 4.0.
32
4.1.27. SetCSC (CSC)
Function: CSC adjusting in Current CSC pattern (CSC1 or CSC2). This command is invalid when
CSC is set OFF or auto luminance control function (SALC command) is set STOP or RUN.
The execution result is saved in system memory by save command execution.
Format: ID SetCSC _ Sel1 _ Sel2 [ _ Data ]
Sel2
012
0 CSC11 (R – R) CSC21 (R – G) CSC31 (R – B)
1 CSC12 (G – R) CSC22 (G – G) CSC32 (G – B)
Sel1
Sel2
Sel1
2 CSC13 (B – R) CSC23 (B – G) CSC33 (B – B)
CSC adjusting value
0 – 1023 Adjusting value in CSC11, CSC22 and CSC33
-255 – 255 Adjusting value in CSC12, CSC13, CSC21, CSC23,
CSC31 and CSC32
Data
Omitted Current setting value display
Response: ID SetCSC _ sel1 [ _ sel2 _ data ]
CSC adjusting value selecting (refer to Format)
0 – 2 CSC adjusting value selecting (refer to Format)
?00 Invalid parameter
sel1
?01 Execution failure
CSC adjusting parameter selecting (refer to Format)
0 – 2 CSC adjusting value selecting (refer to Format)
sel2
Omitted It is omitted when sel1 is “?00” or “?01”.
Current CSC adjusting value selected in sel1 and sel2.
0 – 1023
or -255 – 255
Current CSC adjusting value
data
Omitted It is omitted when sel1 is “?00” or “?01”.
4.1.28. SetFilter (Filter Warning Setting)
Function: To set the hours of interval to show “CHECK FILTER” message.
The execution result is saved in system memory by save command execution. After setting
the warning timer value by using this command, if you change the Sdirection parameter to
Cnt=1, the warning timer setting is changed to time=4000 and if you change the Sdirection
parameter to Cnt=0, the warning timer setting is changed to time=0 automatically. This
command is an exclusive command for front access model.
Format: ID SetFilter [ _ Time ]
Warning timer setting
0 –
30000
Setting time (unit : hour) A setting unit is 100 hours.
Time
omitted Current setting status display
Response: ID SetFilter_ time
Warning timer setting
0 –
30000
Setting time (unit : hour)
?00 Invalid parameter
time
?01 Execution failure