System information

REV 4.0.
26
4.1.14. SAwhite (System Auto White )
Function: Automatic white level adjusting of analog RGB signal in selected input port. The
execution result is saved in system memory by save command execution. Full-bit white
signal is required to input from the selected analog input port when this command is
executed. When Mode of Isig command is not set to 0, this command is not available. It may
take more than 700 msec till the display returns the result string after receiving a command.
Effective inputs: ANALOG, S.ANALOG
Format: ID SAwhite
Response: ID SAwhite [ _ err ]
Results status
Omitted Normal end (automatic adjusting is finished)
?00 Invalid parameter
err
?01 Execution failure
4.1.15. SautoDisp (Auto Display)
Function: Display of stand-by status, failure status, lamp blow-out status by LED indicator and
OSD warning indication (Lamp changer models only). The execution result is saved in
system memory by save command execution.
Format: ID SautoDisp _ Sel [ _ Mode ]
Kind of display
0Reserved
1 Warning indication by OSD (Lamp changer models only)
2 Display of stand-by status by LED.
3 Display of failure status by LED.
4 Display of lamp blow-out status by LED.
Sel
5Reserved
Setting of display
0 Display OFF
1 Sel=1: MESSAGE
Sel=2,3,4: Display ON
2Sel=1:
Omitted Current setting value display
Response: ID SSautoDisp _ sel [ _ mode]
Kind of display
0Reserved
1 Warning indication by OSD (Lamp changer models only)
2 Display of stand-by status by LED.
3 Display of failure status by LED.
4 Display of lamp blow-out status by LED.
5Reserved
?00 Invalid parameter
sel
?01 Execution failure
Setting of display
0 Display OFF
1 Sel=1: MESSAGE
Sel=2,3,4: Display ON
2Sel=1:
mode
Omitted It is omitted when sel is “?00” or “?01”.