System information

25
Response: ID SAgain_ rgb [ _ data ]
R,G or B selecting
0 Red gain fine adjusting
1 Green gain fine adjusting
2 Blue gain fine adjusting
3 Main contrast adjusting (S.ANALOG of model group C)
4 Red clamp level adjusting
5 Green clamp level adjusting
6 Blue clamp level adjusting
?00 Invalid parameter
rgb
?01 Execution failure
Current gain value of the color designated in rgb.
If 255(factory adjusted value) is designated as the gain value, the factory
adjusted value will be returned in the next value operating.
0 – 127 Gain (white level) adjusting value ANALOG of model
group C
0 – 255 Gain (white level) adjusting value ANALOG of model
group A , B and
S.ANALOG of all
models
0 – 127 Clamp level adjusting value ANALOG
0 – 255 Clamp level adjusting value S.ANALOG
data
Omitted It is omitted when rgb is ” ?00 ” or ” ?01 ”.
4.1.13. SAnaTerm (Analog Terminate)
Function: Analog input port termination setting. The execution result is saved in system memory
by save command execution.
Effective inputs: ANALOG, S.ANALOG
Format: ID SAnaTerm _ Sel [ _ Data ]
Analog input port selecting
0ANALOG
Sel
1S.ANALOG
Termination setting
0 Termination OFF
1 Termination ON
Data
Omitted Current setting value display
Response: ID SAnaTerm _ sel [ _ data ]
Selected analog input port
0ANALOG
1S.ANALOG
?00 Invalid parameter
sel
?01 Execution failure
Current termination setting of analog input port designated in sel
0 – 1 Termination setting
data
Omitted It is omitted when sel is “?00” or “?01”.