System information

21
0 Rightward
Infotype =1
Info Name Reflection Access type Applicable product
0 FRONT One-time reflection Front VS-50XLF20U
1 REAR One-time reflection Rear
2 D-FRONT Direct displaying Front
3 D-REAR Direct displaying Rear
4Reserved
5Reserved
6Reserved
7Reserved
8Reserved
9Reserved
Infotype =2
F/W Version
Omitted When “infotype” parameter is ” ?00 ” or ” ?01 ” , “info”
parameter is omitted.
4.1.4. PLampTReset (Lamp Timer Reset)
Function: Lamp timer resetting. The execution result is saved in lamp memory by automatically.
Format: ID PLampTReset _ Flag
Resetting execution flag
0 Lamp timer reset (Current lamp at lamp changer models.)
1 A lamp timer reset
(An exclusive command for lamp changer models.)
Flag
2 B lamp timer reset
(An exclusive command for lamp changer models.)
Response: ID PLampTReset _ err
Result status
0 - 2 Normal end (Lamp timer has been reset)
?00 Invalid parameter
err
?01 Execution failure
4.1.5. PLSearch (Lamp Position Search)
Function: To execute lamp position search for brightness optimization. This command can not be
accepted during stand-by state. It may take dozens seconds till the execution ends. The
execution result is saved in system memory by save command execution. This command is
an exclusive command for lamp changer models.
Format: ID PLSearch _ flag
Execution flag
Flag
0 To search brightest current lamp position.
(Not specified lamp number)
Response: ID PLSearch _ err
Execution result status
0 Normal end
?00 Invalid parameter
err
?01 Execution failure