3.1.10. Pinp (Input Select)
Function: To select input port to display on screen. It may take more than 700 msec till the display
returns the result string after receiving a command. This command is effective only when the
Power State is “Power on state”. Status is automatically saved at shut down.
Format: ID Pinp[ _ Sel ]
Input port to display
0ANALOG
1 DIGITAL
2S.ANALOG
3 S.DIGITAL
4COMPOSITE
5Y/C
Sel
Omitted Current status display
Response: ID Pinp _ sel
Current status display
0ANALOG
1 DIGITAL
2S.ANALOG
3 S.DIGITAL
4COMPOSITE
5Y/C
?00 Invalid parameter
sel
?01 Execution failure
3.1.11. PLampChange (Lamp Change)
Function: To move standby lamp to lighting position. This command can be accepted during
stand-by state. It may take dozens seconds till the execution ends. Status is automatically
saved at shut down. This command is an exclusive command for lamp changer models.
Format: ID PLampChange _ Flag
Execution flag
Flag
0 To move standby lamp to lighting position
Response: ID PLampChange _ err
Execution result status
0 Normal end
?00 Invalid parameter
err
?01 Execution failure