� Easy to connect to programming tool via Ethernet
IP address setting is not required to connect GX Developer (programming tool) to the CPU module
directly (one-to-one connection). Also, the CPU module allows the use of either straight or cross
cable. Ethernet thus realizes easy communication with the CPU module like USB connection,
even operators who are not familiar with the network can easily connect it. (Patent pending)
� Search and display a list of connected CPUs
Using an Ethernet hub, GX Developer can be simultaneously connected to multiple CPUs.
The connected CPUs on the network can be searched and displayed in a list. By selecting a CPU
from the list, it is connected easily even if the IP address is unknown, and the operating status
can be checked.
IP address setting not required!
Direct connection by a straight/cross cable
Check "Ethernet port direct connection."
List of CPUs found in a serach. Identify by the preset label and comment.
Easy
connection
from
the list
Easy
connection,
no parameter
settings
Ethernet
GX Developer
GX Developer
Ethernet
Hub
� Always provide accurate clock data
With the SNTP* clock synchronization function, clock synchronization, which is a bottleneck
factor, is automatically performed. Accurate time of error occurrence can be grasped,
enabling the user to easily confirm the multiple CPU related error occurrence timing.
� Connect to various devices according to applications
High-speed communication with external devices is available via Ethernet. According to
application requirements, various devices can be connected.
Process 1 error logs
XXXX Error 13:15
XXXX Error 13:22
Current time
13:40
Clock data server
* SNTP: Simple Network Time Protocol
Ethernet
Process 2 error logs
XXXX Error 13:07
Current time
13:40
Process 3 error logs
Current time
13:40
XXXX Error 13:10
Server error logs
Easy to confirm how
the error spread.
XXXX Error 13:07 Process 2
XXXX Error 13:10 Process 3
XXXX Error 13:15 Process 1
XXXX Error 13:22 Process 1
Error originated
in the Process 2.
Let's look into it!
Precise
clock
synchronization
Connection
with
various
devices
Access
beyond
hierarchy
GX Developer
The QnU model supports the high-speed, high-capacity CC-Link IE Controller Network to allow
for massive data exchange. It can also communicate with MELSECNET/H, Ethernet, and
CC-Link seamlessly beyond the network type and hierarchy. Each programmable controller on
the network can be monitored/programmed by GX Developer connected via Ethernet.
� Seamless communication across all layers
MELSECNET/H
Controller Network
Seamless
communication
Enterprise level
network
Control level
network
Device level
network
Sensor level
network
Upgraded Function
Specific transmission of data to/from
upper-level servers and various
devices is applicable .
GT SoftGOT1000
Simultaneous connection with multiple external
devices using a hub
Ethernet
Various devices such
as temperature control
Measuring device,
vision sensor, etc.
User applications etc.
GX Developer GOT1000
MELSOFT connection communication MC protocol communication
Socket communication
Response
Command
Ethernet
5 6