Hardware manual
Monitoring the PLC Ladder Programs on a Display
PLC Ladder Monitor Operation Manual
2-7
4 Register the device monitor feature. In GP-Pro EX, from [System Settings], point to [Display
Unit] and select [Extended Settings]. Select the [Device Monitor] checkbox.
5 Save and transfer the project file to the display.
Reference:GP-Pro EX Reference Manual
6 Install the CF Card onto the GP.
Reference:For details on installing a CF Card, see “GP3000 Series Hardware Manual”.
7 Connect the display to communicate with the PLC.
Reference:For details on the connection, see “GP-Pro EX Device Connection Manual”
• The device monitor screen uses a global display window. While the device
monitor is displayed, the screen cannot display other global windows. When
you select the [Device Monitor] checkbox, [Global Window] operation is
automatically set to [Indirect].
• For manual settings, in the display system menu, point to [Offline], select [Main
Unit], and select [Window Settings]. Configure the following settings in [Global
Window Operation]:
Global Window Operation: Indirect
Data Type : BIN
• To monitor the Q/QnA Series with Ethernet Connection, you need to input the
PC station number of the External Device that you want to monitor by GP-Pro
EX.
For the setting of PC station number, see “Mitsubishi Electric Corporation Q/
QnA Series Ethernet Driver” in “GP-Pro EX Device Connection Manual”.