Specifications

5 - 11
5.4 Parameter Settings of Remote I/O Network
To make the remote I/O network operate, it is required to set parameters in both the
remote master station CPU module and the remote I/O station network module using
GX Developer.
(1) Parameter settings for the remote master station
Network settings
1) Starting I/O No.
2) Network No. 1 to 239
3) Total stations Remote master station only
Setting the number of module cards
Network type MNET/H (Remote master)
Set the following
functions as necessary.
Network refresh parameter settings
Settings of valid module No. during other station access
Writing parameter to CPU module
Not
required
Required
To cable connection
Routing parameter settings
Interrupt setting parameter settings
Common parameters
1) Transmission range of each station
(LB/LW, LX/LY setting)
Set the following functions as necessary.
2) Reserved station setting
3) Equal assignment
Supplementary settings
CPU module reset