Specifications

4 - 10
Detailed description of the control data
Device Item Description
(S1) Abnormal completion type
b15 b7 b0
1)
b8 b6
0
00 0
to to
1) Abnormal completion type (bit 7)
Sets the clock data set status at abnormal completion.
0: Does not set the clock data : Does not store the clock data at error occurrence in (S1) +
11 to (S1) 15.
1: Sets clock data : Stores the clock data at error occurrence in (S1) + 11 to (S1)
15.
(S1) + 1 Completion status
Stores the status when an instruction is completed.
0 : Normal
Other than 0 : Abnormal (Refer to Appendix 5 for error codes)
(S1) + 2 Host storage channel
Designates the channel that stores the data to be read.
1 to 8 (channels)
(S1) + 3
Channel used by the sending
station
Stores the channel used by the sending station.
1 to 8 (channels)
(S1) + 4 Sending station network No.
Stores the sending station's network No.
1 to 239: Network No.
(S1) + 5 Sending station number
Stores the station number of the sending station.
1 to 64 : Station number
FF
H
: All station
(S1) + 6 (Use prohibited)
——————
(S1) + 7 Number of resends
1) At instruction execution
Becomes valid when the execution type designated in (S1) is "1: With arrival confirmation."
Set the number of resends when the instruction fails to complete within the monitoring time
designated by (S1) + 8.
0 to 15 (times)
2) At instruction completion
Stores the number of resends executed (result).
0 to 15 (times)
(S1) + 8 Arrival monitoring time
Sets the monitoring time until the instruction completion.
When the instruction fails to complete within the monitoring time, it is abnormally completed.
0 : 10s
1 to 32767 : 1 to 32767s
(S1) + 9 Receive data length
Stores the word count of the receive data stored in (D1) to (D1) + n.
1 to 480 (words)
(S1) + 10 (Use prohibited)
——————
(S1) + 11 Clock set flag
Stores the valid/invalid status of the clock data in (S1) + 12 to (S1) 15.
0: Invalid
1: Valid
(S1) + 12
Year (lower two digits)/month
of abnormal completion
The year (the lower two digits of the 4-digit year) and month are stored as BCD codes.
b15 b7 b0b8
Year (00
H 99H)
to to
Month (00
H 12H)
(S1) + 13
Date/hour of abnormal
completion
The date and hour are stored as BCD codes.
b15 b7 b0b8
Date (01
H
31
H
)
to to
Hour (00
H
23
H
)
(S1) + 14
Minute/second of abnormal
completion
The minute and second are stored as BCD codes.
b15 b7 b0b8
Minute (00
H
59
H
)
to to
Second (00
H
59
H
)