Service manual
2-2. Operation Characteristic Curve
– 5 –
FILE NO. SVM-11015
<Cooling> <Heating>
2-3. Capacity Variation ratio According to Temperature.
<Cooling> <Heating>
0
1
2
3
4
5
6
7
8
9
10
11
12
0 10 20 30 40 50 60 70 80 90 100 110 120
Compressor Speed (RPS)
Current (A)
Conditions
Indoor : DB 20
o
C/WB 15
o
C
Outdoor : DB 7
o
C/WB 6
o
C
Indoor Air Flow : High
Pipe Length : 5m
Voltage : 230V
0
20
40
60
80
100
120
-20 -15 -10 -5 0 5 10
Heating Capacity ratio (%)
Outside Temperature ( ºC)
RAS-10SKVP2-E
RAS-13SKVP2-E
RAS-16SKVP2-E
0
2
4
6
8
10
12
0 102030405060708090100110120
Compressor Speed (RPS)
Current (A)
RAS-10SKVP2-E
RAS-13SKVP2-E
RAS-16SKVP2-E
RAS-10SKVP2-E
RAS-13SKVP2-E
RAS-16SKVP2-E
50
55
60
65
70
75
80
85
90
95
100
105
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
Cooling Capacity ratio (%)
Outside Temperature (
o
C)
Capacity ratio : 100 %=
2.51kW(RAS-10SKVP2-E)
3.52kW(RAS-13SKVP2-E)
4.53kW(RAS-16SKVP2-E)
RAS-10SKVP2-E
RAS-13SKVP2-E
RA
S
-1
6S
KVP2-E
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Outdoor : DB 35
o
C/WB 24
o
C
Indoor Air Flow : High
Pipe Length : 5m
Voltage : 230V
Conditions
Indoor : DB 20
o
C/WB 15
o
C
Outdoor : DB 7
o
C/WB 6
o
C
Indoor Air Flow : High
Pipe Length : 5m
Voltage : 230V