Service manual
BaseGap
②
④
④
③
④
②
③
③
④
②
④
Connector(P10)
Connector(P20)
Stepping motor setscrews
Stepping motor
Blower fan assembly
Blower fan assembly
Blower fan assembly
Blower fan assembly Catch
Temperature/humidity sensor
Temperature/humidity sensor
Drainpan assembly
Drainpan assembly
Connector(P1) Connector(P3)
Solenoid valve Solenoid valve setscrew
Earth wire setscrew Earth wire Plug cord
①5HPRYHWKHUHDUFDVLQJĺ5HIHUHQFH
(7)Removing the rear casing)
②Remove the connector P20 and stepping
motor setscrews(2) to remove the stepping
PRWRUĺ5HPRYLQJDQGUHSODFLQJWKH
stepping motor)
③Remove the connector P10 and tape to
separate the lead wire from the blower fan
guide casing.
④Detach the catch(1) from the blower fan
assembly to remove the
WHPSHUDWXUHKXPLGLW\VHQVRUĺ5HPRYLQJ
and replacing the temperature/humidity
sensor)
①Remove the rear casing.
ĺ5HIHUHQFH5HPRYLQJWKH
rear casing)
②Remove the connector P3 from the
power control board and remove
the solenoid valve setscrew(1) to
remove the solenoid valve.
ĺ5HPRYLQJDQGUHSODFLQJWKH
solenoid valve)
③Remove the earth wire setscrew(1)
to remove the earth wire.
④Remove the connector P1 and
separate the power plug cord wire
from the clamper to remove the
power plug from the gap of the
EDVHĺ5HPRYLQJDQGUHSODFLQJ
the plug cord)
(8)Removing and replacing the stepping motor and temperature/humidity sensor
(9)Removing and replacing the solenoid valve and plug cord
27