Service manual

BaseGap
Connector(P10)
Connector(P20)
Stepping motor setscrews
Stepping motor
Blower fan assembly
Blower fan assembly
Blower fan assembly
Blower fan assembly Catch
Temperature/humidity sensor
Temperature/humidity sensor
Drainpan assembly
Drainpan assembly
Connector(P1) Connector(P3)
Solenoid valve Solenoid valve setscrew
Earth wire setscrew Earth wire Plug cord
5HPRYHWKHUHDUFDVLQJĺ5HIHUHQFH
(7)Removing the rear casing)
Remove the connector P20 and stepping
motor setscrews(2) to remove the stepping
PRWRUĺ5HPRYLQJDQGUHSODFLQJWKH
stepping motor)
Remove the connector P10 and tape to
separate the lead wire from the blower fan
guide casing.
Detach the catch(1) from the blower fan
assembly to remove the
WHPSHUDWXUHKXPLGLW\VHQVRUĺ5HPRYLQJ
and replacing the temperature/humidity
sensor)
Remove the rear casing.
ĺ5HIHUHQFH5HPRYLQJWKH
rear casing)
Remove the connector P3 from the
power control board and remove
the solenoid valve setscrew(1) to
remove the solenoid valve.
ĺ5HPRYLQJDQGUHSODFLQJWKH
solenoid valve)
Remove the earth wire setscrew(1)
to remove the earth wire.
Remove the connector P1 and
separate the power plug cord wire
from the clamper to remove the
power plug from the gap of the
EDVHĺ5HPRYLQJDQGUHSODFLQJ
the plug cord)
(8)Removing and replacing the stepping motor and temperature/humidity sensor
(9)Removing and replacing the solenoid valve and plug cord