Service manual

19
Cleaning inside switch 
ON
ON
OFF
Cleaning 
inside lamp
ON
OFF
Compressor
ON
OFF
Solenoid valve
Tube temperature
Cleaning inside (manual)
ON
OFF
Blower fan
ON
OFF
Operation switch
Cleaning 
inside complete
Cleaning 
inside complete
ON
OFF
Cleaning 
inside switch
ON
OFF
Operation 
mode lamp
max 
20 min.
30 min.
60 min.
10 min.
Operation OFF
Start Cleaning inside
Cleaning inside (automatic)
max 
20 min.
Cleaning inside switch 
ON
30 min.
10 min.
60 min.
Tube temperature 
45
Tube temperature 
45
4545