Service manual
16
6.3 Timing Charts
E16S
Operation mode
OFF
SH
LO
60%
Tank full/ Power OFF
Hi
Mi
Power
ON
Mode button
ON
Easy
ON
ON
OFF
Operation switch
Easy
dehumidifying
Easy
dehumidifying
ON
OFF
Compressor
ON
OFF
Float switch
Auto
Blower fan
Tank full Drain
Power
OFF
Humidify
Easy dehumidifying/ Mode
max
3 min.
3
sec.
Mi for 2 sec.
at start-up.
min
7 min.
Auto
※ When room temperature is
between 20℃ and 27℃.
ON
OFF
Tank full light
Auto
50%
Low temp
Room
temperature
Low temp
Decrease in room
temperature
14℃
16℃
Increase in room
temperature
3
sec.