Specifications
20
19
MELSECNET(Ⅱ)-MELSECNET/10
Gateway Set
(Q6KT-NETGW-□□)
■Use a Q2AS based MELSECNET(Ⅱ)/10 gateway to gradually convert MELSECNET(Ⅱ)
stations to MELSECNET/10. MELSECNET/10 is backwards compatible with
Q Series via MELSECNET/H.
【Before transition】 【Transitional step】 【Transition completed】
Step-by-step replacement with Q Series
Set model name
Q6KT-NETGW-SS
Q6KT-NETGW-RS
Q6KT-NETGW-RB
Q6KT-NETGW-TS
Q6KT-NETGW-TB
Q6KT-NETGW-□□
A1SJ71QLP21
A1SJ71QLP21
A1SJ71QBR11
A1SJ71QLP21
A1SJ71QBR11
A1SJ71AP21
A1SJ71AT21B
A1SJ71AR21
A1S35B A1S61PN Q2ASCPU
■Gateway set options
Main part MELSECNET/10 partMELSECNET(Ⅱ)/B part
Implement gradual migration from MELSECNET(Ⅱ)
to MELSECNET/10.
[Example] Partial replacement of MELSECNET(Ⅱ), from AnS/QnAS Series
network modules to Q Series network modules
MELSECNET
(Ⅱ)
Please check the cautions and restrictions for the gateway
station network parameters etc. in the related manuals.
A1
A2 A5
A3 A4
AnS/QnAS Series
Q Series
An
Qn
A2
A3 Q4
Q5
A1
MELSEC
NET
(Ⅱ)
MELSEC
NET
/10
MELSECNET
/H(10)
Q1
Q2 Q5
Q3 Q4
Use a gateway to
incorporate the
Q Series system
into the existing
system.
Step-by-step
replacement for the
entire system conversion
to Q Series.
Reading
the model
name
Network type: MELSECNET(Ⅱ)
S: SI optical fiber cable (double loop)
R: Coaxial cable (double loop)
T: Twisted pair cable (bus)
Network type: MELSECNET/10
S: SI optical fiber cable (double loop)
B: Coaxial cable (bus)
Gateway set
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
MELSECNET/10
Gateway set Q Series
MELSECNET(Ⅱ)
NET(Ⅱ)
Local
station
NET/10
Control
station
NET/10
Normal
station
GatewayGateway
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
MELSECNET(Ⅱ), MELSECNET/B
Local Station Data Link Module
Upgraded AnS local station data link modules permit a direct
Q Series connection to existing networks as local stations.
( )
A1SJ71AP23Q
A1SJ71AR23Q
A1SJ71AT23BQ
■Replace AnS/QnAS Series MELSECNET(Ⅱ), MELSECNET/B stations with Q Series systems.
The MELSECNET(Ⅱ)/B local station data link modules allow a Q Series system to directly connect to existing
NET(Ⅱ)/NET/B data link system via a QA1S□B extension base unit.
Model
A1SJ71AP23Q
A1SJ71AR23Q
A1SJ71AT23BQ
MELSECNET(Ⅱ) local station data link module for SI optical fiber cable
MELSECNET(Ⅱ) local station data link module for coaxial cable
MELSECNET/B local station data link module for shielded twisted pair cable
■Local station data link module options
Outline
●Specifications
Supported CPUs
High Performance Model QCPUs [Q02(H), Q06H, Q12H, and Q25HCPU] and Universal Model QCPUs
whose first five digits of the serial number are 13102 or later.
Compatible extension base units
QA1S□B or QA□B with A-A1S module conversion adapter (A1ADP-SP)
Number of modules per CPU
Send point range can be further increased by mounting up to 6 modules per CPU.
Network parameters
Minimal setup required, as network parameters settings are automatically detected by the module.
Link refresh setting
Link refresh setting is not automatically detected. Hence, FROM/TO instructions within sequence program to
enable send/receive cyclic data are required.
Sample programs for link refresh are provided in "A/QnA
-
> Q Conversion Support Tool". The sample
program can be used to create a QCPU program which may reduce development time.
For details, please contact your local Mitsubishi sales office or representative.
MELSECNET(Ⅱ)
MELSECNET(Ⅱ) Local station data link module
High performance model QCPU
Master station
Local station
[Example] MELSECNET(Ⅱ) configuration incorporating Q Series
Local station
QA1S51B *
1
QA1S65B
QA1S68B
Extension base unit
with 1 slot
(power supply
module not required)
*1: No further extensions can be made to QA1S51B as it has not got an Extension Cable Connector.
This unit cannot be used in conjunction with QA6□B and QA6ADP with A5□B nor can QA6ADP be
used in conjunction with A6□B.