Technical information

62
MITSUBISHI ELECTRIC
MICRO CONTROLLERS
/// MICRO CONTROLLERS
Digital extension modules
There are 4 different extension modules
available for the ALPHA 2, which allow the
controller to be e x tended through addi
-
tional inputs or outputs. The modules are
inserted directly into the ALPHA 2 and
therefore do not take up any additional
space.
The AL2-4EX has the additional feature that
2 inputs may be used as high-speed coun
-
ters with a c ounting frequency of 1 kHz.
All modules feature photocoupler isolation
for all I/Os.
MITSUBISHI
EO1
EO3
EO4
EO2
4EYR
RELAY
OUTPUT
Digital extension modules specifications AL2-4EX-A2 AL2-4EX AL2-4EYR AL2-4EYT
Inputs
Integratedinputs 4 4
Input voltage 220–240 V AC 24 VDC (+20%, -15%)
Input current
7.5 mA at 240V AC(50 Hz),
9.0 mA at 240 V AC (60 Hz)
5.4m1mAat24VDC
Outputs
Integrated outputs 4 4
Output type Relay Transistor
Switchedvoltage(max.) V 250VAC,30VDC 524VDC
Rated current A 2 A per output 1 A per output
Electrical specifications
Power Supply AC range (+10 %, -15%) 220–240 V AC 24 V DC 100–240 V AC 24 V DC
Mechanical specifications
Dimensions (W x Hx D) mm 53.1 x 90 x 24.5 53.1 x 90 x 24.5 53.1 x 90 x 24.5 53.1 x 90 x 24.5
Order information
Art. no. 142522 142521 142523 142524
Note: EI1 and EI2 of the AL2-4EX can be used as high-speed counter inputs. In eachcasetheresponsetimeforthehigh-speedcounterinputswillbe0.5msor less.
The AL2 digitalextension modules cannot be used with theAL2-10MR series
POWER
24V DC
MITSUBISHI
POWER
V1+
SLD
+
K-type Thermocouple -50~450°C
AL2-2TC-ADP
L1+
-
L1-
V2+
L2-
V1-
L2+
V2-
SLD
OUTPUT
CH1
CH2
0~10V
450°C 450°C
CH1
CH2
-50°C
-50°C
Line
Line
CH1
CH2
POWER
24V DC
MITSUBISHI
POWER
V1+
I1-
+
PT100 -50~200°C
AL2-2PT-ADP
L1+
-
L1-
V2+
L2-
V1-
L2+
V2-
I2-
OUTPUT
CH1
CH2
0~10V
200°C 200°C
CH1
CH2
-50°C
-50°C
Line
Line
CH1
CH2
MITSUBISHI
2DA
+
V1+
I1+
VI1-
-
V2+
I2+
VI2-
POWER
24V DC
ANALOG
OUTPUT
ANALOG
OUTPUT
Analog extension modules
The analog extension modules signifi-
cantly increase the range of applications
for the ALPHA 2. With these modules it is
possible to output voltage or current sig-
nals or to measure temperatures.
Three different analog extension modules
are available:
The AL2-2DA offers two additional ana-
log outputs for the ALPHA 2 and con-
verts a digital input value into a voltage
or a current. This module is inserted
directly onto the ALPHA 2.
The AL2-2PT-ADP connects an external
Pt100 sensor to convert temperature
readings into analog signals (0 10 V).
The AL2-2TC-ADP connects thermocouple
sensors (K type) to convert temperature
readings into analog signals (0 10 V).
Analog extension modules specifications AL2-2DA AL2-2PT-ADP AL2-2TC-ADP
Analog inputs
Integratedinputs 2 2
Connectabletemperature sensors
Pt100 sensor
Temp. coefficient3.850ppm/°C(IEC751)
Thermocouple(K type), isolated type
(IEC 584-1 1977, IEC 584-2 1982)
Compensated range -50 +200 °C -50 +450 °C
Analog outputs
Integrated outputs 2
Analog output
range
voltage 0 10 V DC (5 k –1M)—
current 4 20 mA (max. 500 )—
Electrical specifications
Number of channels 2 2 2
PowerSupply 24VDC(-15–+10%),70mA 24VDC(-15–+20%),1W 24VDC(-15–+20%),1W
Mechanical specifications
Dimensions (W x Hx D) mm 53.1 x 90 x 24.5 35.5 x 90 x 32.5 35.5 x 90 x 32.5
Order information
Art. no. 151235 151238 151239
Note: The AL2-2DA module can not be used with the AL2-10MR series