Technical information
117
MITSUBISHI ELECTRIC
LVS
LOW VOLTAGE SWITCH GEARS ///
General Purpose Contactors
Handling of the contactors
S-N10CX to S -N65CX units can all be mounted
on DIN rail (35 mm wide).
A variety of auxiliary blocks and optional featu-
res are available including:
앬
Standard front clip-on auxiliary contact blocks
(4-pole-type and 2-pole-type)
앬
Low-level signal front-clip-on auxiliary con-
tact blocks
앬
Side clip-on auxiliary contact blocks
앬
Surge absorbers (varistor and CR models)
앬
Surge absorbers with LED operating indicators
앬
Mechanical interlocks
Compact arc quenching and magnet layout
greatly reduces installation space.
The coil rating is displayed in a location readily
visible even after the unit is installed onto the
panel.
Contacts are visible when the cover is removed,
allowing them to b e checked easily.
Compact, modular extensions and an
energy-saving design – these are the
main requirements set by users of
contactors and auxiliary contac tors.
Requirements that the MS-N series from
Mitsubishi Electric fulfill.
The main benefits:
앬
Easy mounting and wiring
앬
Easy inspection
앬
Built-in surge absorber (from S-N50)
앬
Safety and speedy terminal functions
앬
Thermo plastic improves the barrier
strength
앬
Coil boasts lower coil consumption
앬
Improvement of Electromagnet
(DC electromagnet with AC operation)
앬
Less noise nor surge from coil
앬
Conform to IEC947-4-1, EN-Standards
앬
Wide range for rated continuous cur
-
rent I
th
from 20 A to 1000 A
SN-20
MITSUBISHI ELECTRIC
SN-400
Three-phase motor ratings IEC category AC3 for Contactors
Contactor
AC-operated S-N10CX S-N11CX S-N12CX S-N18CX S-N20CX S-N21CX S-N25CX S-N35CX S-N50CX S-N65CX
DC-operated — SD-N11CX SD-N1 2CX — — SD-N21CX — SD-N35CX SD-N50 SD-N65
AC 380–440 V kW 4 5.5 5.5 7.5 11 11 15 18.5 22 30
Rated continuous current I
th
A2020202532325060 80100
Auxiliarycontacts(standard) 1NOor1NC 1NOor1NC 1NO+1NC — 1NO+1NC 2NO+2NC 2NO+2NC 2NO+2NC 2NO+2NC 2NO+2NC
Thermal Overload Relays
Type
TH-N12KPCX TH-N18KPCX TH-N20KPCX TH-N20TAKPCX TH-N60KPCX
Settingrange 0.1–13A 1–18A 0.2–22A 18–40A 12–65A
Three-phase motor ratings IEC category AC3 for Contactors
Contactor
AC-operated S-N80 S-N95 S-N125 S-N150 S-N180 S-N220 S-N300 S-N400 S-N600 S-N800
DC-operated SD-N80 SD-N95 SD-N125 SD-N150 — SD-N220 SD-N300 SD-N400 SD-N600 SD-N800
AC 380–440 V kW 45 55 60 75 90 132 160 220 330 440
Rated continuous current I
th
A 135 150 150 200 260 260 350 450 800 1000
Auxiliarycontacts(standard) 2NO+2NC 2NO+2NC 2NO+2NC 2NO+2NC 2NO+2NC 2NO+2NC 2NO+2NC 2NO+2NC 2NO+2NC 2NO+2NC
Thermal Overload Relays
Type
TH-N60TAKP TH-N120KP TH-N120TAKP TH-N220RHKP TH-N400RHKP TH-N600KP
Setting range 54 –105 A 34 – 100 A 85 – 150 A 65 –250 A 85 – 400 A 200 – 800 A