Technical information

87
MITSUBISHI ELECTRIC
INVERTER
INVERTER ///
Overview Internal Options
Overview External Options
External options Description Remarks/Specifications Type
Applicable
inverter
Art. no.
Control panel
(parameter unit)
Optional control panel
Further details are provided by your Mitsubishi
Sales office orin the technicalcataloguefor fre-
quency inverters.
FR-PA02-02 FR-E500 103686
Interactive control panelwith LCD display (8 languages).
FR-PU04 All 67735
FR-PU07 All 166134
Interactive standard control panel FR-DU07 FR-A700 / FR-F700 157514
For mounting on the switchgear cabinet FR-PA07 FR-D700/FR-700 214795
Control panel cover
CoverforthebacksideofthecontrolpanelFR-PA02-02 or FR-PU04 for installation in switchgear
cabinet, for instance
Connection adapter integrated. FR-ESP FR-E500 125323
Connection cable for
remote control panel
Cable for a remoteconnection of the controlpanelFR-PU04orFR-PU07. Availablelength:1;2.5and5m FR-A5CBL All
1 m: 70727
2.5m:70728
5 m: 70729
Adapter Connectionadapter for FR-DU07
Required for remote connection of the FR-DU07
with FR-A5CBL
FR-ADP
FR-A700
FR-F700
157515
Interfacecable
Communications cable for RS232 or RS485 interface to connect
an external personal computer
Length 3 m; can be used for example with the
setup/configuration software
SC-FR PC All 88426
USB-RS232 converter Port converter adapter cable from RS-232 to USB USB specification 1.1, 0.35 m long USB-RS232 FR-D700, FR-F700 155606
VFD setup software
Parameterization and setupsoftware for Mitsubishi Electric inverter.
Further details are provided by your Mitsubishi
Sales office orin the technicalcataloguefor fre
-
quency inverters.
All 500series 159746
FR-Configurator All 700series 190586
DIN rail mounting set Adapter to mount the frequency inverter from 1.5 kon a DIN rail
When using theDIN rail adapters,
filters can not be footprint mounted.
FR-UDA 01
FR-S500E
(<0.75 k)
130833
FR-UDA 02
FR-S500E
(>1.5 k)
130832
EMC noise filter Noisefilter forcompliance with EMC directives.
Please ask your distributor for more details
FFR -첸첸,
FR-, FN -첸첸
All
AC chokes
For increased efficiency, reduction of mains feedback and compensation
of voltage fluctuations.
FR-BAL-B
FR-D700, FR-E700,
FR-E500, FR-A700,
FR-F700
DC reactor DC reactorfor compensationof voltage fluctuations. FR-HEL
FR-D700, FR-E700,
FR-A700, FR-F700
Brake units
For an improvementof the brakecapacity. For highinertia loads and active loads. Used in combi
-
nation with a resistor unit.
FR-BU2,
MT-BU5 +,
MT-BR5
BU-UFS+RUFC
All
Externalbrake resistors To improvethe brake capacityof the inverter; isused in combination with a brake unit FR-ABR(H)
FR-D700, FR-E700,
FR-E500, FR-A500
Internal options Description Remarks/Specifications Type
Applicable
inverter
Art. no.
16-bit digital input
Interface for the input of the frequencysetting via4-digit BCD
or 16-bit binary code, setting of gain and bias supported.
Input: 24 V DC; 5 mA; open collector
or switching signal, sinkor sourcelogic
FR-A7AX FR-F700 / FR-A700 156775
FR-A7AX E kit FR-E700 210668
Digital output
Selectable of 43 standard output signals of the inverter can
be output at the open collector. Theoutputs areisolated with optocouplers.
Output load: 24V DC; 0.1 A,
sink or source logic
FR-A7AY FR-F700 / FR-A700 156776
Expansion analog output
Selectabl e2 of 18 additional signals (e.g. output frequency, output voltage, output current )
can be output and indicated atthe analog output.
Display on measuring gauge: 20 mA DC or 5 V (10 V) DC
Output:max.010VDC;020mA;
Resolution: 3 mV at voltage output,
1 mA at current output, accuracy: ±10%
FR-A7AY E kit FR-E700 210669
Relay output
Selectable 3 of 43 standard output signals of the inverter canbe outputthrough
relay terminals.
Switchingload: 230 V AC/0.3 A, 30 VDC/0.3 A
FR-A7AR FR-F700 / FR-A700 156777
FR-A7AR E kit FR-E700 210670
Vector control and
orientation/encoder
Vector control with encodercan be performed.
5 V TTL differential
1024–4096 pulse
11 30 V HTL complimentary
FR-A7AP FR-A700 166133
The main spindlecan be stoppedat a fixed position (orientation) in combination with a pulse
encoder. The motorspeed is sent back and the speed is maintained constant.
Communi-
cations
CC-Link
Option board for the integrationof afrequency inverter into a CC-Link network. Th eoperation,
display functions, and parameter settings can be controlled by a PLC.
Maximum transfer distance:
1200 m (at 156kBaud)
FR-E5NC FR-E500 104558
FR-A7NC FR-F700 / FR-A700 156778
FR-A7NC E kit FR-E700 210671
CAN Open
Option board for integration of a frequency inverter ina CANOpen network.
Operation, display functions andparameter settings canbe controlled by a
computer (PC etc.) or a PLC.
Maximum transfer rate:1 MBaud
OI-FR-E5NCO FR-E500 139378
FR-A7NCA FR-A700 141403
FR-A7NCA E kit FR-E700 210705
Ethernet
Option board for integration of a frequency inverter in a Ethernet network.
Operation, display functions andparameter settings canbe controlled by a
computer (PC etc.) or a PLC.
Only NA version FR-A7NE FR-A700 on request
LonWorks
Option board for integration of a frequency inverter in a LonWorks network.
Operation, display functions andparameter settings canbe controlled by a
computer (PC etc.) or a PLC.
Connection of up to 64 inverters
supported. Maximum transferrate: 78 kBaud
FR-A7NL FR-F700/ FR-A700 156779
FR-A7NL E kit FR-E700 210672
Profibus/DP
Option board for the integration of a frequency inverter into a Profibus/DP network.
The operation, display functions,and parameter settingscan be controlled by a computer
(PC etc.) or a PLC.
Connectionof up to 126 inverterssupported. Maxi-
mum transfer rate: 12 MBaud
FR-A7NP FR-F700 / FR-A700 158524
FR-A7NP E kit FR-E700 210673
D-Sub9 connection adapter for FR-A7NP FR-D-Sub9 FR-F700 / FR-A700 191751
Connection of up to 42 inverters supported. FR-E5NP FR-E500 104556
DeviceNet
TM
Option board for the integration of a frequency inverter into a DeviceNet.
The operation, display functions,and parameter settingscan be controlled by
a computer (PC etc.) or a PLC.
Maximum transfer rate: 10MBaud
FR-A7ND FR-F700 / FR-A700 158525
FR-A7ND E kit FR-E700 210704
FR-E5ND F R-E500 104557
SSCNET III
Option board for the integration of a frequency inverterinto the Mitsubishi Electric servosys-
tem networkSSCNET III.The operation and display functions can be controlledby Motion Con-
troller (Q172H CPU, Q173H CPU).
Maximum transfer rate: 50 MBaud FR-A7NS FR-A700 141403
Automation Book_UK_2008.prn
Automation Book_UK_2008
Dienstag, 8. April 2008 18:25:52
Farbprofil: Deaktiviert
Komposit Standardbildschirm