Technical information
85
MITSUBISHI ELECTRIC
INVERTER
INVERTER ///
General Operating Conditions for all Inverters
Specifications
FR-D700 FR-S500E FR-E700 FR-E500 FR-F700 FR-A700
Ambient temperature in operation
-10 °C to +50°C
(non-freezing)
-10 °C to +50°C
(non-freezing)
-10 °C to +50°C
(non-freezing)
-10 °C to +50°C
(non-freezing)
햲
FR-F740: -10 °C to +50 °C;
FR-F746: -10 °C to +40 °C
(non-freezing)
햳
-10 °C to +50°C
(non-freezing)
Storage temperature
햴
-20 to +65 °C -20to +65 °C -20 to +65 °C -20 to +65 °C -20 to+65 °C -20 to +65 °C
Ambient humidity
Max. 90 %
(non-conden s ing)
Max. 90 %
(non-condensing)
Max. 90 %
(non-condensing)
Max. 90 %
(non-conden s ing)
Max. 90 %
(non-condensing)
Max. 90 %
(non-condensing)
Altitude
Max. 1000 m abovesea
level.
Max. 1000 m abovesea
level.
햵
Max. 1000 m abovesea
level.
Max. 1000 m abovesea
level.
햵
Max. 1000 m abovesea
level.
Max. 1000 m abovesea
level.
Protectivestructure EnclosedtypeIP20 EnclosedtypeIP20 EnclosedtypeIP20 EnclosedtypeIP20
FR-F740: IP 00 / IP 20
햶
FR-F746: IP 54
IP 00/ IP 20
Shock resistance
10 G (3 times each
in 3 directions)
10 G (3 times each
in 3 directions)
10 G (3 times each
in 3 directions)
10 G (3 times each
in 3 directions)
10 G (3 times each
in 3 directions)
10 G (3 times each
in 3 directions)
Vibration resistance Max. 5.9 m/s
2
0.6 G: resistance
to vibrations from
10 to 55 Hz for 2hours
along all 3axes
Max. 5.9 m/s
2
(JIS 60068-2-6)
0.6 G: resistance
to vibrations from
10 to 55 Hz for 2hours
along all 3axes
Max. 0.6 G
(2.9 m/s² or less for the
04320 or more.)
Max. 5.9 m/s² orless
(2.9 m/s² or less for the
models from
FR-A740-04320 or above)
Ambient conditions
For indoor use only, avoid
environments containing
corrosive gases, install in a
dust-free location.
For indoor use only, avoid
environments containing
corrosive gases, install in a
dust-free location.
For indoor use only, avoid
environments containing
corrosive gases, install in a
dust-free location.
Forindooruseonly,avoid
environments containing
corrosive gases, install in a
dust-free location.
Forindooruseonly,avoid
environments containing
corrosive gases,
install in a dust-free loca-
tion.
Forindooruseonly,avoid
environments containing
corrosive gases, install in a
dust-free location.
Approvals
UL/CSA/CE/EN/GOST/
CCC
UL/CSA/CE/EN/GOST/
CCC
UL/CSA/CE/EN/GOST/
CCC
UL/CSA/CE/EN/GOST/
CCC
FR-F740:
CE/UL/cUL/DNV/GOST;
FR-F746: CE/GOST / CCC
CE/UL/cUL/DNV /GOS T/ CCC
Remarks:
햲
For selection of the loadcharacteristics with variable torque the max. temperature is 40 °C.
햳
For selection of the loadcharacteristics with a 120 % overload rating the max. temperature is 40 °C (F740) and 30°C (F746).
햴
Theproductmayonlybeexposedtothefullextremesofthistemperature range for short periods (e.g. during transportation).
햵
After that derate by 3 % for everyextra 500m up to 2500 m.
햶
When the cable bushing for the optional expansion cardsis brokenout the unit has anIP 00 protection rating.