Technical information
78
MITSUBISHI ELECTRIC
INVERTER
/// INVERTER
MITSUBISHI
Improved func tions and equipment fea
-
tures such as an integrated USB interface,
an integrated “digital dial” with display,
improved efficiency in the low speed
rangeaswellasthepossibilityofusing
one of many option cards such as the
exchangeable I/O cards, for instance, ren
-
der the FR-E700 a commercial universal
genius for many applications, such as
앬
textile machines
앬
door and gate actuators
앬
elevators
앬
cranes
앬
material handling systems
Improved speed/power limitation guar
-
antees increased machine protec tion.
This reliably prevents damage to the
machines.
The FR-E740 is available in the output
powerrange0.4to15kW.
The frequency cinverters are desiged for
3-phase connections 380 to 480 V AC
(50/60 Hz).
The output frequency ranges from
0.2 to 400 Hz.
Product line
FR-E740 EC
016 026 040 060 095 120 170 230 300
Output
Applicablemotor capacity
햲
kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15
Rated capacity
햳
kVA
1.2 2.0 3.0 4.6 7.2 9.1 13 17.5 23.0
Rated current
햴
A 1.6 (1.4) 2.6 (2.2) 4.0 (3.8) 6.0 (5.4) 9.5 (8.7) 12 17 23 30
Overload capacity
햵
150 % of rated motor capacity for 60 s; 200 % for 3 s
Voltage
햶
3phase, 0 V up to power supply voltage
Input
Power supply voltage 3phase, 380–480V AC, -15 %/+10 %
Voltage range 325–528 V AC at 50/60 Hz
Frequencyrange 50/60Hz±5%
Rated input capacity
햷
kVA 1.5 2.5 4.5 5.5 9.5 12 17 20 28
Control-
specifi-
cations
Control method
V/f control,
optimum excitation control,general-purpose magnetic flux vector control or advanced magnetic flux vector control
Modulation control Sine evaluated PWM, Soft PWM
PWM switching frequency kHz 0.7–14.5, user adjustable
Frequency range Hz 0,2–400
Possible starting torque ³ 200 % / 0.5 Hz (advanced magnetic flux vector control (3.7K or less))
Torque boost Manual torque boost
Acceleration / deceleration time 0.01 to 360 s, 0.1 to 3600 s (may be set individually for acceleration and deceleration)
Acceleration / deceleration
characteristics
Linear or S-pattern acceleration/deceleration mode selectable
Braking
torque
DC braking Operating frequency: 0–120 Hz, operating time: 0–10 s, voltage: 0–30 %(externallyadjustable)
Motor protection Electronic motor protection relay (rated current useradjustable)
Control
signals for
operation
Frequency setting signal 0–5 V DC, 0–10 V DC, 0/4–20 mA, From control panel (parameter unit)
Input signals
Any of 7 signals can be selected using parameters 178 to 184 (input terminal function selection): You can select from among multi-speed selection, remote setting,stop-on con-
tact selection, second function selection, terminal 4 input selection, JOG operation selection, PID control valid terminal, brake opening completion signal,external thermal input,
PU-externaloperation switchover, V/F switchover, outputstop, start self-holding selection, forwardrotation, reverse rotation command, inverter reset, PU-NET operation
switchover, external-NET operation switchover, command source switchover, inverter operation enable signal, and PU operation externalinterlock
Operation functions
Maximum/minimum frequency setting, frequency jump operation, external thermal relay input selection, automatic restart after instantaneous power failure operation, for-
ward/reverse rotation prevention, remote setting, brake sequence, second function, multi-speed operation, stop-on contact control, droop control, regeneration avoidance, slip
compensation, operation mode selection, offline auto tuning function, PID control, computer link operation (RS-485)
Output
signals
operation status
Can be selected usign parameters 190 to 192 (output termnal function selection): inverter operation, up-to-frequency, overload alarm, output frequency detection, regenerative
brake prealarm, electronic thermal relay function prealarm, inverter operation ready, output current detection, zero current detection, PID lower limit,PID upper limit, PID for
-
ward/reverserotation output, brake opening request, fan alarm, heatsink overheat pre-alarm, decelerationat aninstantaneous power failure, PIDcontrol activated, during retry,
life alarm, currentaverage value monitor,remote output, alarm output, fault output, fault output 3, and maintenance timer alarm
analog signal 0–10V DC
Others
Dimensions (BxHxT) 140 x 150 x 114 140 x 150 x 114 140 x 150 x 135 140 x 150 x 135 140 x 150 x 135 150 x220 x 147 150 x 220 x147 220 x 260x 190 220 x 260 x190
Order information
Art. no. 211955 211956 211957 211958 211959 211960 211961 211962 211963
FR-E700
Remarks:
햲
The applicable motor capacityindicated is themaximum capacityapplicablefor useof the Mitsubishi 4-pole standard motor.
햳
The rated output capacity indicated assumes that theoutput voltageis 440V.
햴
The rated output current in theparenthesesapplies when low acousticnoise operation is to beperformed at an ambient temper aturehigherthan 40 °C withtheparameter
72 (PWM frequency selection) value set to 2 kHz or higher.
햵
The overload capacity indicatedin % is the ratio of theoverload current to the inverters rated current. Forrepeated duty, allow time for the inverter and motor to returnto or
below the temperature and 100 % load.
햶
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changedwithin the setting range. However, the pulsevoltage value
of theinverter output side voltage remains unchanged at about Ö2
that of the power supply.
햷
The power supply capacity varies with the value of the power supply side inverter impedance (including those of the input reactor and cables).